One of the most widely used methods for headspace analysis is described by the United States Environmental Protection Agency (USEPA). Originally developed by the R.S. Kerr USEPA Laboratory in Ada, Oklahoma as a "high quality, defendable, and documented way to measure" methane, ethane, and ethene, [7] [8] RSKSOP-175 is a standard operating procedure (SOP) and an unofficial method employed by ...
For the analysis of volatile compounds, a purge and trap (P&T) concentrator system may be used to introduce samples. The target analytes are extracted by mixing the sample with water and purge with inert gas (e.g. Nitrogen gas) into an airtight chamber, this is known as purging or sparging.
Gas chromatography-mass spectrometry is a widely used analytical technique for the detection of volatile compounds. Ionization techniques most frequently used in forensic toxicology include electron ionization (EI) or chemical ionization (CI), with EI being preferred in forensic analysis due to its detailed mass spectra and its large library of ...
Flow injection analysis (FIA) Fourier transform infrared spectroscopy (FTIR) G. Gas chromatography (GC) Gas chromatography-mass spectrometry (GC-MS)
Gas chromatography (GC) is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture. [ 1 ]
Chromatography employs continuous adsorption and desorption on a packed bed of a solid to purify multiple components of a single feed stream. In a laboratory setting, mixture of dissolved materials are typically fed using a solvent into a column packed with an appropriate adsorbent, and due to different affinities for solvent (moving phase ...
Although thousand different substances can be determined in a single gas chromatography–mass spectrometry or liquid chromatography–mass spectrometry experiment, due to the low concentration of analytes, practical measurements (see selective ion monitoring) are limited to a smaller number (10-20) of analytes.
[4] [5] Mass spectrometry ionization techniques requiring the sample to be in the gas phase have similar concerns. Electron ionization (EI) in mass spectrometry requires samples that are small molecules, volatile, and thermally stable, similar to that of gas chromatography. This ensures that as long as GC is performed on the sample before ...