  2. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    The US National Electrical Code permitted the use of the supply neutral wire as the equipment enclosure connection to ground from 1947 to 1996 for ranges (including separate cooktops and ovens) and from 1953 to 1996 for clothes dryers, whether plug-in or permanently fixed, provided that the circuit originated in the main service panel. Normal ...

  3. Grounding kit - Wikipedia

    en.wikipedia.org/wiki/Grounding_kit

    Grounding kits for different diameters Part of a tin-plated ripple. Grounding kits / Earthing kits are composed of two main components, a clamp and a cable. The clamp will be screwed on a coaxial cable and in case of lightning strokes in the antenna installation, the voltage will be diverted over a ripple in the clamp with the combined cable and will be earthed / grounded by this way.

  4. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    Permanently installed electrical equipment, unless not required to, has permanently connected grounding conductors. Portable electrical devices with metal cases may have them connected to earth ground by a pin on the attachment plug (see AC power plugs and sockets). The size of power grounding conductors is usually regulated by local or ...

  5. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    FMC may be used as an equipment grounding conductor if specific provisions are met regarding the trade size and length of FMC used, depending on the amperage of the circuits contained in the conduit. In general, an equipment grounding conductor must be pulled through the FMC with an ampacity suitable to carry the fault current likely imposed on ...

  6. Isolated ground - Wikipedia

    en.wikipedia.org/wiki/Isolated_ground

    The primary reason for the use of isolated grounds (IG) is to provide a noise-free ground return, separate from the equipment grounding (EG) return. The EG circuit includes all of the metal conduit, outlet boxes, and metal enclosures that contain the wiring and must be grounded to provide a safe return path in case of fault currents.

  7. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    A ground connection that is missing or of inadequate capacity may not provide the protective functions as intended during a fault in the connected equipment. Extra connections between ground and circuit neutral may result in circulating current in the ground path, stray current introduced in the earth or in a structure, and stray voltage.

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Ring ground - Wikipedia

    en.wikipedia.org/wiki/Ring_ground

    The halo is connected to the main building ground, which may include an underground ring ground outside the building, with vertical conductors especially in the corners of the building. Electrical equipment is also often placed in fully enclosed metal cabinets, which function as Faraday cages to further protect the equipment. The halo may be ...

  1. Ads

    related to: grounding conduit for electrical equipment kit