enow.com Web Search

  1. Ad

    related to: occupant load calculation worksheet
  2. pdffiller.com has been visited by 1M+ users in the past month

    A Must Have in your Arsenal - cmscritic

Search results

  1. Results from the WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The CLF is the cooling load at a given time compared to the heat gain from earlier in the day. [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load.

  3. ASHRAE 55 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_55

    ANSI/ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy is an American National Standard published by ASHRAE that establishes the ranges of indoor environmental conditions to achieve acceptable thermal comfort for occupants of buildings. It was first published in 1966, and since 2004 has been updated every three to six years.

  4. Sensitivity analysis of an EnergyPlus model - Wikipedia

    en.wikipedia.org/wiki/Sensitivity_analysis_of_an...

    In this case, it was first necessary to identify the salient model parameters characterizing the building occupant. The parameters that had the most impact on total energy use are listed according to importance for both warm and cold climates. Important parameters in a warm climate zone: Equipment load (High) Ventilation rate (High) Equipment ...

  5. Factor of safety - Wikipedia

    en.wikipedia.org/wiki/Factor_of_safety

    In engineering, a factor of safety (FoS) or safety factor (SF) expresses how much stronger a system is than it needs to be for an intended load.Safety factors are often calculated using detailed analysis because comprehensive testing is impractical on many projects, such as bridges and buildings, but the structure's ability to carry a load must be determined to a reasonable accuracy.

  6. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  7. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    The starting point in carrying out an estimate both for cooling and heating depends on the exterior climate and interior specified conditions. However, before taking up the heat load calculation, it is necessary to find fresh air requirements for each area in detail, as pressurization is an important consideration.

  8. Occupant-centric building controls - Wikipedia

    en.wikipedia.org/wiki/Occupant-centric_building...

    The selection of occupancy sensing devices depends on the size of the space being monitored, the budget for sensors, the desired accuracy, the goal of the sensor (detecting occupant presence or count), and security considerations. Unlike occupant presence data, acquiring occupant preference data requires direct feedback from building occupants.

  9. Design load - Wikipedia

    en.wikipedia.org/wiki/Design_load

    A crane's rated load is its Safe Working Load (SWL) and the design load (DL) is, (p 90) [1] = The dynamic lift factor for offshore cranes in the range 10 kN < SWL ≤ 2500 kN is not less than =.(p 84) [1] Thus for a crane with a SWL of 2000 kN (~200 tonne) its design load is not less than, = = The minimum breaking load (MBL) for the combined capacity of reeves of a steel wire hoisting rope ...

  1. Ad

    related to: occupant load calculation worksheet