enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Fusible link - Wikipedia

    en.wikipedia.org/wiki/Fusible_link

    An electrical fusible link is a type of electrical fuse that is constructed simply with a short piece of wire typically four American wire gauge (AWG) sizes smaller than the wire that is being protected. For example, an AWG 16 fusible link might be used to protect AWG 12 wiring.

  3. High resistance connection - Wikipedia

    en.wikipedia.org/wiki/High_resistance_connection

    A high-resistance connection (HRC) is a hazard that results from loose or poor connections in traditional electrical accessories and switchgear which can cause heat to develop, capable of starting a fire. [1] Glowing connections occur when relatively high current exists in a relatively large resistance object. Heat comes from power dissipation ...

  4. IEC 60269 - Wikipedia

    en.wikipedia.org/wiki/IEC_60269

    IEC 60269-7 – Low-voltage fuses – Part 7: Supplementary requirements for fuse-links for the protection of batteries and battery systems; In IEC standards, the replaceable element is called a fuse link and the assembly of fuse link and fuse holder is called a fuse. North American standards call the replaceable element only the fuse.

  5. Fuse (electrical) - Wikipedia

    en.wikipedia.org/wiki/Fuse_(electrical)

    In electronics and electrical engineering, a fuse is an electrical safety device that operates to provide overcurrent protection of an electrical circuit. Its essential component is a metal wire or strip that melts when too much current flows through it, thereby stopping or interrupting the current.

  6. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    A combination AFCI breaker provides protection against parallel arcing (line to neutral), series arcing (a loose, broken, or otherwise high resistance segment in a single line), ground arcing (from line or neutral to ground), overload, and short circuit. The AFCI will open the circuit if dangerous arcing is detected.

  7. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  8. The fire that killed four people, including three children, has been linked to a dryer, police said Wednesday. The fire, at 118 Union St. and reported at about 7:10 p.m., ... FULL STORY Police ...

  9. Oxygen firebreak - Wikipedia

    en.wikipedia.org/wiki/Oxygen_firebreak

    A fire in an oxygen tube approaching an oxygen firebreak. An oxygen firebreak, also known as a fire stop valve or fire safety valve, is a thermal fuse designed to extinguish a fire in the delivery tube being used by a patient on oxygen therapy and stop the flow of oxygen if the tube is accidentally ignited.