enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Full load hour - Wikipedia

    en.wikipedia.org/wiki/Full_load_hour

    Full Load hour is a measure of the degree of utilisation of a technical system. [1] [2] [3] Full load hours refer to the time for which a plant would have to be operated at nominal power in order to convert the same amount of electrical work as the plant has actually converted within a defined period of time, during which breaks in operation or partial load operation can also occur.

  3. Capacity factor - Wikipedia

    en.wikipedia.org/wiki/Capacity_factor

    If a plant is only needed during the day, for example, even if it operates at full power output from 8 am to 8 pm every day (12 hours) all year long, it would only have a 50% capacity factor. Due to low capacity factors, electricity from peaking power plants is relatively expensive because the limited generation has to cover the plant fixed costs.

  4. Nameplate capacity - Wikipedia

    en.wikipedia.org/wiki/Nameplate_capacity

    Nameplate capacity, also known as the rated capacity, nominal capacity, installed capacity, maximum effect or gross capacity, [1] is the intended full-load sustained output of a facility such as a power station, [2] [3] electric generator, a chemical plant, [4] fuel plant, mine, [5] metal refinery, [6] and many others. Nameplate capacity is the ...

  5. Load-following power plant - Wikipedia

    en.wikipedia.org/wiki/Load-following_power_plant

    Their startup or shutdown took many hours as they were designed to operate at maximum power, and heating up steam generators to the desired temperature took time. [2] Nuclear power generation has been also portrayed as inflexible by anti-nuclear activists and the German Federal Environment Ministry, while others claimed "that the plants might ...

  6. Utilization factor - Wikipedia

    en.wikipedia.org/wiki/Utilization_factor

    The motor load factor is then 12/15 = 80%. The motor above may only be used for eight hours a day, 50 weeks a year. The hours of operation would then be 2800 hours, and the motor use factor for a base of 8760 hours per year would be 2800/8760 = 31.96%. With a base of 2800 hours per year, the motor use factor would be 100%.

  7. Turlough Hill Power Station - Wikipedia

    en.wikipedia.org/wiki/Turlough_Hill_Power_Station

    [5] [6] The power station is designed to generate electricity at times of peak demand and is instantly dispatchable: it can go from standstill to full generation within 70 seconds, compared with 12 hours for some thermal plants. [7] It can generate electricity at full load for up to six hours per day and has a round trip energy efficiency of 75%

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    Capability curves for generators with full converters: D-shape (red), rectangular (green), triangular (blue) The inverter-based resources (like solar photovoltaic (PV) generators, doubly-fed induction generators and full-converter wind generators, also known as "Type 3" and "Type 4" turbines [5]) need to have reactive capabilities in order to contribute to the grid stability, yet their ...