Search results
Results from the WOW.Com Content Network
If the electrical axis is between -30° and -90° this is considered left axis deviation. If the electrical axis is between +90° and +180° this is considered right axis deviation (RAD). RAD is an ECG finding that arises either as an anatomically normal variant or an indicator of underlying pathology.
Bifascicular block is characterized by right bundle branch block with left anterior fascicular block, or right bundle branch block with left posterior fascicular block on electrocardiography. Complete heart block could be the cause of syncope that is otherwise unexplained if bifascicular block is seen on electrocardiography. [1]
This open-heart surgery is designed to relieve the right ventricular outflow tract stenosis by careful resection of muscle and to repair the VSD. [58]: 154 The right ventricle outflow tract can be reconstructed using mainly 2 procedures: a transannular patch (TAP) or a pulmonary valve-sparing procedure (PVS). The decision on the type of the ...
The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane.. In electrocardiography, left axis deviation (LAD) is a condition wherein the mean electrical axis of ventricular contraction of the heart lies in a frontal plane direction between −30° and −90°.
A left posterior fascicular block (LPFB), also known as left posterior hemiblock (LPH), is a condition where the left posterior fascicle, which travels to the inferior and posterior portion of the left ventricle, [1] does not conduct the electrical impulses from the atrioventricular node.
A right bundle branch block (RBBB) is a heart block in the right bundle branch of the electrical conduction system. [1] During a right bundle branch block, the right ventricle is not directly activated by impulses traveling through the right bundle branch. However, the left bundle branch still normally activates the left ventricle.
LAFB cannot be diagnosed when a prior inferior wall myocardial infarction (IMI) is evident on the ECG. IMI can also cause extreme left-axis deviation, but will manifest with Q-waves in the inferior leads II, III, and aVF. By contrast, QRS complexes in the inferior leads should begin with r-waves in LAFB. [citation needed]
The axis may be normal but may be deviated to the left or right. [4] There are also partial blocks of the left bundle branch: "left anterior fascicular block" (LAFB) [5] and a "left posterior fascicular block" (LPFB). [5] This refers to the block after the bifurcation of the left bundle branch.