Search results
Results from the WOW.Com Content Network
Thus a meter with a 50 μA movement will have a "sensitivity" of 20,000 Ω/V. "Per volt" refers to the fact that the impedance the meter presents to the circuit under test will be 20,000 Ω multiplied by the full-scale voltage to which the meter is set. For example, if the meter is set to a range of 300 V full scale, the meter's impedance will ...
The emulator always stops on cycle boundaries. The user has visibility to any signal or memory contents in the design without the need to set up probes before the run. While visibility is provided also for past time, the amount of time that it can show in the past might be limited in some cases to the depth of the emulator's trace memory.
For example, a meter with a sensitivity of 1000 ohms per volt would draw 1 milliampere at full scale voltage; if the full scale was 200 volts, the resistance at the instrument's terminals would be 200 000 ohms and at full scale, the meter would draw 1 milliampere from the circuit under test. For multi-range instruments, the input resistance ...
86Box is an IBM PC emulator for Windows, Linux and Mac based on PCem that specializes in running old operating systems and software that are designed for IBM PC compatibles. . Originally forked from PCem, it later added support for other IBM PC compatible computers as we
PC Guide color lime green. Line outputs usually present a source impedance of from 100 to 600 ohms. The voltage can reach 2 volts peak-to-peak with levels referenced to −10 dBV (300 mV) at 10 kΩ. The frequency response of most modern equipment is advertised as at least 20 Hz to 20 kHz, which corresponds to the range of human hearing. Line ...
Two terminals carry the current from and to the meter, while the other two allow the meter to measure the voltage across the resistor. In this arrangement, the power source is connected in series with the resistance to be measured through the external pair of terminals, while the second pair connects in parallel with the galvanometer which ...
Pinning an AOL app to your Windows 10 Start menu is a simple task, follow the steps below. Open the Windows Start menu and click All apps. Locate the AOL app in the list. Right-click on the app name. A small menu will appear. Click Pin to Start to add this app to your Start menu.
In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t