enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  3. Ground continuity monitor - Wikipedia

    en.wikipedia.org/wiki/Ground_continuity_monitor

    A GCM or ground continuity monitor (also called a ground integrity monitor or ground continuity tester) is an electrical safety device that monitors the impedance to ground of a temporary electrical circuit and can provide indication (or protective trip) in the event impedance rises to an unsafe value. A GCM is either an external testing device ...

  4. Insulation monitoring device - Wikipedia

    en.wikipedia.org/wiki/Insulation_monitoring_device

    An insulation monitoring device monitors the ungrounded system between an active phase conductor and earth.It is intended to give an alert (light and sound) or disconnect the power supply when the resistance between the two conductors drops below a set value, usually 50 kΩ (sample of IEC standard for medical applications).

  5. Fault indicator - Wikipedia

    en.wikipedia.org/wiki/Fault_indicator

    In electric power distribution networks, a fault indicator is a device which provides visual or remote indication of a fault on the electric power system. Also called a faulted circuit indicator (FCI), [1] the device is used in electric power distribution networks as a means of automatically detecting and identifying faults to reduce outage time.

  6. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    The ground loop still exists, but the two sides of the loop are close together, so stray magnetic fields induce equal currents in both sides, which cancel out. Break in the shield Create a break in the signal cable shield conductor. [5] The break should be at the load end. This is often called ground lifting. It is the simplest solution; it ...

  7. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    American-standard AFCI (arc-fault circuit interrupter) unit circa 2018. The white 'pigtail' is a low-power neutral connection, hard-wired into the unit. Starting with the 1999 version of the National Electrical Code in the United States, and the 2002 version of the Canadian Electrical Code in Canada, the national codes require AFCIs in all ...

  8. No fault found - Wikipedia

    en.wikipedia.org/wiki/No_fault_found

    No fault found (NFF), no trouble found (NTF) or no defect found (NDF) are terms used in the field of maintenance, where a unit is removed from service following a complaint of a perceived fault by operators or an alarm from its BIT (built-in test) equipment. The unit is then checked, but no anomaly is detected by the maintainer.

  9. Driver monitoring system - Wikipedia

    en.wikipedia.org/wiki/Driver_Monitoring_System

    Specifically, the driver monitoring system includes a CCD camera placed on the steering column which tracks the face, [2] via infrared LED detectors. [3] If the driver is not paying attention to the road ahead and a dangerous situation is detected, the system will warn the driver by flashing lights, warning sounds.