Doppler Optical Coherence Tomography is an extension of OCT, where it combines the Doppler effect principle to achieve high resolution tomographic images in biological tissues. And because of its high resolution and velocity sensitivity, there are many applications in the medical field. The basic phenomenon of Doppler OCT can be explained below.
Optical coherence tomogram of a fingertip. It is possible to observe the sweat glands, having "corkscrew appearance" Interferometric reflectometry of biological tissue, especially of the human eye using short-coherence-length light (also referred to as partially-coherent, low-coherence, or broadband, broad-spectrum, or white light) was investigated in parallel by multiple groups worldwide ...
Medical optical imaging is the use of light as an investigational imaging technique for medical applications, pioneered by American Physical Chemist Britton Chance.Examples include optical microscopy, spectroscopy, endoscopy, scanning laser ophthalmoscopy, laser Doppler imaging, optical coherence tomography, and transdermal optical imaging.
Initial efforts to measure blood flow using OCT utilized the Doppler effect. [41] [42] By comparing the phase of successive A-mode scans, the velocity of blood flow can be determined via the Doppler equation. This was deemed Optical Doppler Tomography; the development of spectral domain OCT (SD-OCT) and swept-source OCT (SS-OCT) greatly ...
The photoacoustic Doppler effect is a type of Doppler effect that occurs when an intensity modulated light wave induces a photoacoustic wave on moving particles with a specific frequency. The observed frequency shift is a good indicator of the velocity of the illuminated moving particles. A potential biomedical application is measuring blood flow.
In place of the stethoscope, a Doppler ultrasound beam measures the blood flow pulsations in intracranial and extracranial segments of the ophthalmic artery. The non-invasive ICP meter based on this method gradually increases the pressure over the eyeball and intraorbital tissues so that the blood flow pulsation parameters in two sections of ...
SV-OCT uses the inter-frame variance of image intensities to compute blood flow. Areas that have high flow will have higher motion of scattering particles and this information is encoded in the speckle pattern. [citation needed] SV-OCT has advantages for microvasculature imaging due to its high sensitivity and independence to the Doppler angle.
Octave, symbol: oct., a unit of measurement in electronics; Octans, abbreviation: Oct, a constellation; Office of the Chief Technologist, a manager at the NASA Institute for Advanced Concepts; Optical coherence tomography, an imaging method; Olefin conversion technology, a method in industrial chemistry