Search results
Results from the WOW.Com Content Network
RAID (/ r eɪ d /; redundant array of inexpensive disks or redundant array of independent disks) [1] [2] is a data storage virtualization technology that combines multiple physical data storage components into one or more logical units for the purposes of data redundancy, performance improvement, or both.
A Redundant Array of Inexpensive Servers (RAIS) or Redundant Array of Independent Nodes (RAIN) is the use of multiple servers to maintain service if one server fails. This is similar in concept to how RAID turns a cluster of ordinary disks into a single block device.
Diagram of a RAID 1 setup. RAID 1 consists of an exact copy (or mirror) of a set of data on two or more disks; a classic RAID 1 mirrored pair contains two disks.This configuration offers no parity, striping, or spanning of disk space across multiple disks, since the data is mirrored on all disks belonging to the array, and the array can only be as big as the smallest member disk.
RAID 01, also called RAID 0+1, is a RAID level using a mirror of stripes, achieving both replication and sharing of data between disks. [3] The usable capacity of a RAID 01 array is the same as in a RAID 1 array made of the same drives, in which one half of the drives is used to mirror the other half.
RAID—Redundant Array of Independent Disks; RAII—Resource Acquisition Is Initialization; RAIT—Redundant Array of Inexpensive Tapes; RAM—Random-Access Memory; RARP—Reverse Address Resolution Protocol; RAS—Reliability, Availability and Serviceability; RAS—Remote access service; RC—Region Code; RC—Release Candidate; RC—Run Commands
When a disk fails, erased data is rebuilt using all the operational disks in the array, the bandwidth of which is greater than that of the fewer disks of a conventional RAID group. Furthermore, if an additional disk fault occurs during a rebuild, the number of impacted tracks requiring repair is markedly less than the previous failure and less ...
In the adjacent diagram, data are concatenated from the end of disk 0 (block A63) to the beginning of disk 1 (block A64); end of disk 1 (block A91) to the beginning of disk 2 (block A92). If RAID 0 were used, then disk 0 and disk 2 would be truncated to 28 blocks, the size of the smallest disk in the array (disk 1) for a total size of 84 blocks.
Like all RAID (Redundant Array of Independent Disks), Intel RST RAID employs two or more physical hard disks which the operating system will treat as a single disk, in order to increase redundancy which avoids data loss (except RAID 0), and/or to increase the speed at which data is written to and/or read from a disk.