Search results
Results from the WOW.Com Content Network
An SCR can be brought from blocking mode to conduction mode in two ways: Either by increasing the voltage between anode and cathode beyond the breakover voltage, or by applying a positive pulse at the gate. Once the SCR starts conducting, no more gate voltage is required to maintain it in the ON state.
Some operating conditions require switching in each half-wave and thus very fast operation. Examples are control sections with very fast behavior or a required current limitation with low element resistance in the cold state. In this operating mode, the controller changes the phase angle α of the thyristor ignition timing.
The Jazelle instruction set is well documented as Java bytecode.However, ARM has not released details on the exact execution environment details; the documentation provided with Sun's HotSpot Java Virtual Machine goes as far as to state: "For the avoidance of doubt, distribution of products containing software code to exercise the BXJ instruction and enable the use of the ARM Jazelle ...
Like an SCR, when a voltage pulse is present on the gate terminal, the device turns on. The main difference between an SCR and a Triac is that both the positive and negative cycle can be turned on independently of each other, using a positive or negative gate pulse. Similar to an SCR, once the device is turned on, the device cannot be turned off.
In most applications, the gate current comes from MT2, so quadrants 1 and 3 are the only operating modes (both gate and MT2 positive or negative against MT1). Other applications with single polarity triggering from an IC or digital drive circuit operate in quadrants 2 and 3, where MT1 is usually connected to positive voltage (e.g. +5V) and gate ...
low SCR: in case of a short circuit, the current is proportional to SCR, therefore generators with low SCR require less protection and thus are cheaper; low SCR allows shorter air gap and lower excitation field, both decreasing the size (an cost) of the generator; with low SCR the amounts of iron and copper are reduced, lowering the cost; high SCR:
The SCR can be calculated for each point on an electrical grid. A point on a grid having a number of machines with an SCR above a number between 1 and 1.5 has less vulnerability to voltage instability. Hence, such a grid is known strong grid or power system. A power system (grid) having a lower SCR has more vulnerability to grid voltage ...
The safe operating area curve is a graphical representation of the power handling capability of the device under various conditions. The SOA curve takes into account the wire bond current carrying capability, transistor junction temperature, internal power dissipation and secondary breakdown limitations.