DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...
DOAS Diagram. Moisture Removal Efficiency (MRE) is a measure of the energy efficiency of any dehumidification process. Moisture removal efficiency is the water vapor removed from air at a defined inlet air temperature and humidity, divided by the total energy consumed by the dehumidification equipment during the same time period, including all fan and pump energy needed to move air and fluids ...
Demand control ventilation is an attractive alternative to standard design in these situations because DCV systems only supply the outdoor airflow necessary to serve the occupants in a space. Therefore, the above-described energy is not wasted in this system type.
Displacement ventilation is best suited for taller spaces (higher than 3 meters [10 feet]). [2] Standard mixing ventilation may be better suited for smaller spaces where air quality is not as great a concern, such as single-occupant offices, and where the room height is not tall (e.g., lower than 2.3 meters [7.5 feet]).
AMCA Publication 200 - Air Systems. Part 1 of the Fan Application Manual, this publication provides basic information necessary for the design of energy efficient air systems. This edition includes examples in both the Inch-Pound and SI systems as the reader is provided with basic information on air systems. AMCA Publication 201 - Fans and ...
A chilled beam is a type of radiation/convection HVAC system designed to heat and cool large buildings through the use of water. [1] This method removes most of the zone sensible local heat gains and allows the flow rate of pre-conditioned air from the air handling unit to be reduced, lowering by 60% to 80% the ducted design airflow rate and the equipment capacity requirements.
In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.
Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor ...