Search results
Results from the WOW.Com Content Network
An enthalpy–entropy chart, also known as the H–S chart or Mollier diagram, plots the total heat against entropy, [1] describing the enthalpy of a thermodynamic system. [2] A typical chart covers a pressure range of 0.01–1000 bar , and temperatures up to 800 degrees Celsius . [ 3 ]
Vapor-compression refrigeration [6] For comparison, a simple stylized diagram of a heat pump's vapor-compression refrigeration cycle: 1) condenser, 2) expansion valve, 3) evaporator, 4) compressor (Note that this diagram is flipped vertically and horizontally compared to the previous one) [7] Temperature–entropy diagram of the vapor-compression cycle.
The pressure on a pressure-temperature diagram (such as the water phase diagram shown above) is the partial pressure of the substance in question. A phase diagram in physical chemistry , engineering , mineralogy , and materials science is a type of chart used to show conditions (pressure, temperature, etc.) at which thermodynamically distinct ...
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.
However, the liquid–vapor boundary terminates in an endpoint at some critical temperature T c and critical pressure p c. This is the critical point. The critical point of water occurs at 647.096 K (373.946 °C; 705.103 °F) and 22.064 megapascals (3,200.1 psi; 217.75 atm; 220.64 bar). [3]
A saturation dome uses the projection of a P–v–T diagram (pressure, specific volume, and temperature) onto the P–v plane. The points that create the left-hand side of the dome represent the saturated liquid states, while the points on the right-hand side represent the saturated vapor states (commonly referred to as the “dry” region).
R407C pressure-enthalpy diagram, isotherms between the two saturation lines Main article: List of refrigerants Refrigerants may be divided into three classes according to their manner of absorption or extraction of heat from the substances to be refrigerated: [ citation needed ]
At first glance there is little resemblance between the charts, but if the chart is rotated by ninety degrees and looked at in a mirror the resemblance becomes apparent. The Mollier diagram coordinates are enthalpy and humidity ratio. The enthalpy coordinate is skewed and the lines of constant enthalpy are parallel and evenly spaced. The ASHRAE ...