Search results
Results from the WOW.Com Content Network
A water heater that maintains desired temperature by turning the applied power on and off (as opposed to continuously varying electrical voltage or current) based on temperature feedback is an example application of bang–bang control. Although the applied power switches from one discrete state to another, the water temperature will remain ...
The Home Energy Saver is built on DOE-2, a computer program for building heating and cooling energy analysis and design. [3] DOE-2 performs a thermal load simulation that accounts for heating and cooling equipment and thermal distribution efficiencies, infiltration, and thermostat management. [4]
The energy factor metric only applies to residential water heaters, which are currently defined by fuel, type, and input capacity. [5] Generally, the EF number represents the thermal efficiency of the water heater as a percentage, since it is an average of the ratio of the theoretical heat required to raise the temperature of water drawn to the amount of energy actually consumed by the water ...
A tempering valve mixes enough cold water with the hot water from the heater to keep the outgoing water temperature fixed at a more moderate temperature, often set to 50 °C (122 °F). Without a tempering valve, reduction of the water heater's setpoint temperature is the most direct way to reduce scalding.
Step 3: Attach a water hose to the drain valve at the bottom of your water heater and run the hose outside or into a nearby drain. You can use any generic hose for this step, and a garden hose ...
An electric heater is an electrical device that converts an electric current into heat. [1] The heating element inside every electric heater is an electrical resistor , and works on the principle of Joule heating : an electric current passing through a resistor will convert that electrical energy into heat energy.
The power through the thermostat is provided by the heating device and may range from millivolts to 240 volts in common North American construction, and is used to control the heating system either directly (electric baseboard heaters and some electric furnaces) or indirectly (all gas, oil and forced hot water systems).
The building balance point temperature is the outdoor air temperature when the heat gains of the building are equal to the heat losses. [1] Internal heat sources due to electric lighting, mechanical equipment, body heat, and solar radiation may offset the need for additional heating although the outdoor temperature may be below the thermostat set-point temperature.