A variable-frequency drive (VFD) is a type of frequency changer used for speed control of AC motors such as used for pumps and fans. The speed of a synchronous or induction AC motor is dependent on the frequency of the AC power supply, so changing frequency allows the motor speed to be changed. This allows fan or pump output to be varied to ...
Small variable-frequency drive Chassis of above VFD (cover removed). A variable-frequency drive (VFD, or adjustable-frequency drive, adjustable-speed drive, variable-speed drive, AC drive, micro drive, inverter drive, variable voltage variable frequency drive, or drive) is a type of AC motor drive (system incorporating a motor) that controls speed and torque by varying the frequency of the ...
Speed feedback is typically provided via an integral AC tachometer. Eddy current drives are slip-controlled systems the slip energy of which is necessarily all dissipated as heat. Such drives are therefore generally less efficient than AC/DC-AC conversion based drives. The motor develops the torque required by the load and operates at full speed.
A High-volume low-speed fan. A high-volume low-speed (HVLS) fan is a type of mechanical fan greater than 7 feet (2.1 m) in diameter. [1] HVLS fans are generally ceiling fans although some are pole mounted. HVLS fans move slowly and distribute large amounts of air at low rotational speed– hence the name "high volume, low speed."
The affinity laws (also known as the "Fan Laws" or "Pump Laws") for pumps/fans are used in hydraulics, hydronics and/or HVAC to express the relationship between variables involved in pump or fan performance (such as head, volumetric flow rate, shaft speed) and power. They apply to pumps, fans, and hydraulic turbines. In these rotary implements ...
Fan assemblies with this control input provide the ability to adjust the rotational speed of the fan without changing the input voltage delivered to the cooling fan assembly. A variable rotation speed allows the cooling rate to be adjusted to meet demand, quietening the fan and saving energy when full speed is not required.
Brushless motors are commonly used as pump, fan and spindle drives in adjustable or variable speed applications as they are capable of developing high torque with good speed response. In addition, they can be easily automated for remote control. Due to their construction, they have good thermal characteristics and high energy efficiency. [20]
Where noise is an issue, larger, slower-turning fans are quieter than smaller, faster fans that can move the same airflow. Fan noise has been found to be roughly proportional to the fifth power of fan speed; halving the speed reduces the noise by about 15 dB. [22] Axial fans may rotate at speeds of up to around 38,000 rpm for smaller sizes. [23]