enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Intraocular pressure - Wikipedia

    en.wikipedia.org/wiki/Intraocular_pressure

    A patient in front of a tonometer. Intraocular pressure (IOP) is the fluid pressure inside the eye. Tonometry is the method eye care professionals use to determine this. IOP is an important aspect in the evaluation of patients at risk of glaucoma. [1] Most tonometers are calibrated to measure pressure in millimeters of mercury .

  3. Goldmann Applanation Tonometer - Wikipedia

    en.wikipedia.org/wiki/Goldmann_Applanation_Tonometer

    Theoretically, average corneal rigidity (taken as 520 μm for GAT) and the capillary attraction of the tear meniscus cancel each other out when the flattened area has the 3.06 mm diameter contact surface of the Goldmann prism, which is applied to the cornea using the Goldmann tonometer with a measurable amount of force from which the IOP is ...

  4. Ocular tonometry - Wikipedia

    en.wikipedia.org/wiki/Ocular_tonometry

    Impression tonometry (also known as indentation tonometry) measures the depth of corneal indentation made by a small plunger carrying a known weight. The higher the intraocular pressure, the harder it is to push against and indent the cornea. For very high levels of IOP, extra weights can be added to make the plunger push harder. [14]

  5. Imbert-Fick law - Wikipedia

    en.wikipedia.org/wiki/Imbert-Fick_law

    Armand Imbert (1850-1922) and Adolf Fick (1829-1901) both demonstrated, independently of each other, that in ocular tonometry the tension of the wall can be neutralized when the application of the tonometer produces a flat surface instead of a convex one, and the reading of the tonometer (P) then equals (T) the IOP," whence all forces cancel each other.

  6. Schiøtz tonometer - Wikipedia

    en.wikipedia.org/wiki/Schiøtz_tonometer

    The Schiotz tonometer consists of a curved footplate which is placed on the cornea of a supine patient. A weighted plunger attached to the footplate sinks into the cornea. A scale then gives a reading depending on how much the plunger sinks into the cornea, and a conversion table converts the scale reading into IOP measured in mmHg.

  7. List of optometric abbreviations - Wikipedia

    en.wikipedia.org/wiki/List_of_optometric...

    Family ocular history F/U: Follow up appointment GH: General health G(M)P: General (medical) practitioner HA: Headaches HARC: Harmonious abnormal retinal correspondence HM: Hand motion vision – state distance Hx: History IOL: Intra-ocular lens IOP: Intra-ocular pressure ISNT: Inferior, Superior, Nasal, Temporal rule used to assess optic disc ...

  8. Prism cover test - Wikipedia

    en.wikipedia.org/wiki/Prism_Cover_Test

    The prism cover test (PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists, orthoptists, and optometrists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]

  9. Ocular hypertension - Wikipedia

    en.wikipedia.org/wiki/Ocular_hypertension

    Ocular hypertension is the presence of elevated fluid pressure inside the eye (intraocular pressure), usually with no optic nerve damage or visual field loss. [ 1 ] [ 2 ] For most individuals, the normal range of intraocular pressure is between 10 mmHg and 21 mmHg. [ 3 ]