enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Standard RAID levels - Wikipedia

    en.wikipedia.org/wiki/Standard_RAID_levels

    Diagram of a RAID 1 setup. RAID 1 consists of an exact copy (or mirror) of a set of data on two or more disks; a classic RAID 1 mirrored pair contains two disks.This configuration offers no parity, striping, or spanning of disk space across multiple disks, since the data is mirrored on all disks belonging to the array, and the array can only be as big as the smallest member disk.

  3. geom raid5 - Wikipedia

    en.wikipedia.org/wiki/Geom_raid5

    geom_raid5 is a storage module created for the FreeBSD operating system. It facilitates RAID5 functionality without the need of a hardware RAID controller.. geom_raid5 allows storage of large amounts of data to be protected against disk failure, while providing good throughput performance.

  4. RAID - Wikipedia

    en.wikipedia.org/wiki/RAID

    RAID 6 requires a minimum of four disks. As with RAID 5, a single drive failure results in reduced performance of the entire array until the failed drive has been replaced. [11] With a RAID 6 array, using drives from multiple sources and manufacturers, it is possible to mitigate most of the problems associated with RAID 5.

  5. Nested RAID levels - Wikipedia

    en.wikipedia.org/wiki/Nested_RAID_levels

    One drive from each of the RAID 5 sets could fail without loss of data; for example, a RAID 50 configuration including three RAID 5 sets can tolerate three maximum potential simultaneous drive failures (but only one per RAID 5 set). Because the reliability of the system depends on quick replacement of the bad drive so the array can rebuild, it ...

  6. Disk array controller - Wikipedia

    en.wikipedia.org/wiki/Disk_array_controller

    Those RAID systems made their way to the consumer market, for users wanting the fault-tolerance of RAID without investing in expensive SCSI drives. Fast consumer drives make it possible to build RAID systems at lower cost than with SCSI, but most ATA RAID controllers lack a dedicated buffer or high-performance XOR hardware for parity calculation.

  7. Intel Rapid Storage Technology - Wikipedia

    en.wikipedia.org/wiki/Intel_Rapid_Storage_Technology

    The Intel RAID ROM is the firmware in the motherboard BIOS that is used to create the RAID array. Note: The RST drivers can be used for RAID and also on a single drive as it contains an AHCI driver. There is a bug in the version 12.5.0.1066 RST driver, which cause TRIM commands not to pass through the RAID driver to the drives.

  8. mdadm - Wikipedia

    en.wikipedia.org/wiki/Mdadm

    MD can handle devices of different lengths, the extra space on the larger device is then not striped. RAID 1 – Mirror. RAID 4 – Like RAID 0, but with an extra device for the parity. RAID 5 – Like RAID 4, but with the parity distributed across all devices. RAID 6 – Like RAID 5, but with two parity segments per stripe.

  9. Data striping - Wikipedia

    en.wikipedia.org/wiki/Data_striping

    RAID In some RAID configurations, such as RAID 0, failure of a single member drive of the RAID array causes all stored data to be lost. In other RAID configurations, such as a RAID 5 that contains distributed parity and provides redundancy, if one member drive fails the data can be restored using the other drives in the array. LVM2