Search results
Results from the WOW.Com Content Network
A modern self-contained HPLC Schematic representation of an HPLC unit (1) solvent reservoirs, (2) solvent degasser, (3) gradient valve, (4) mixing vessel for delivery of the mobile phase, (5) high-pressure pump, (6) switching valve in "inject position", (6') switching valve in "load position", (7) sample injection loop, (8) pre-column (guard column), (9) analytical column, (10) detector (i.e ...
For a small amount of entrained gas in a drilling fluid, the degasser can play a major role of removing small bubbles that a liquid film has enveloped and entrapped. [1] In order for it to be released and break out the air and gas such as methane, H 2 S and CO 2 from the mud to the surface, the drilling fluid must pass through a degassing technique, and it can be accomplished by the equipment ...
[2] [3] For example, before casting aluminium alloys, argon bubbles are injected into liquid aluminium using a rotary degasser. The argon bubbles rise to the surface, bringing with them some of the dissolved hydrogen. The degassing step reduces the occurrence of hydrogen gas porosity. In the steel making process, this method is used very ...
Degassing, also known as degasification, is the removal of dissolved gases from liquids, especially water or aqueous solutions. There are numerous methods for removing gases from liquids. There are numerous methods for removing gases from liquids.
A control chart is a more specific kind of run chart. The control chart is one of the seven basic tools of quality control, which also include the histogram, pareto chart, check sheet, cause and effect diagram, flowchart and scatter diagram. Control charts prevent unnecessary process adjustments, provide information about process capability ...
The charged aerosol detector (CAD) is a detector used in conjunction with high-performance liquid chromatography (HPLC) and ultra high-performance liquid chromatography (UHPLC) to measure the amount of chemicals in a sample by creating charged aerosol particles which are detected using an electrometer.
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
The sample is first subjected to analysis by HPLC and then is subjected to mass analysis. Different types of mass analyzers, ToF, qudrupole, etc., can be used in the MS. [ 5 ] Common solvents used in normal or reversed phase LC such as water, acetonitrile, and methanol are all compatible with ESI, yet a LC grade solvent may not be suitable for MS.