enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Acid dissociation constant - Wikipedia

    en.wikipedia.org/wiki/Acid_dissociation_constant

    Conversely, when pH = pK a, the concentration of HA is equal to the concentration of A −. The buffer region extends over the approximate range pK a ± 2. Buffering is weak outside the range pK a ± 1. At pH ≤ pK a − 2 the substance is said to be fully protonated and at pH ≥ pK a + 2 it is fully dissociated (deprotonated).

  3. Henderson–Hasselbalch equation - Wikipedia

    en.wikipedia.org/wiki/Henderson–Hasselbalch...

    The Henderson–Hasselbalch equation can be used to model these equilibria. It is important to maintain this pH of 7.4 to ensure enzymes are able to work optimally. [10] Life threatening Acidosis (a low blood pH resulting in nausea, headaches, and even coma, and convulsions) is due to a lack of functioning of enzymes at a low pH. [10]

  4. Dissociation constant - Wikipedia

    en.wikipedia.org/wiki/Dissociation_constant

    The concentration of water, [H 2 O], is omitted by convention, which means that the value of K w differs from the value of K eq that would be computed using that concentration. The value of K w varies with temperature, as shown in the table below. This variation must be taken into account when making precise measurements of quantities such as pH.

  5. Gran plot - Wikipedia

    en.wikipedia.org/wiki/Gran_plot

    The Gran plot is based on the Nernst equation which can be written as = + ⁡ {+} where E is a measured electrode potential, E 0 is a standard electrode potential, s is the slope, ideally equal to RT/nF, and {H +} is the activity of the hydrogen ion.

  6. Buffer solution - Wikipedia

    en.wikipedia.org/wiki/Buffer_solution

    A buffer solution is a solution where the pH does not change significantly on dilution or if an acid or base is added at constant temperature. [1] Its pH changes very little when a small amount of strong acid or base is added to it. Buffer solutions are used as a means of keeping pH at a nearly constant value in a wide variety of chemical ...

  7. Tris - Wikipedia

    en.wikipedia.org/wiki/Tris

    In general, as temperature decreases from 25 °C to 5 °C the pH of a tris buffer will increase an average of 0.03 units per degree. As temperature rises from 25 °C to 37 °C, the pH of a tris buffer will decrease an average of 0.025 units per degree.

  8. Determination of equilibrium constants - Wikipedia

    en.wikipedia.org/wiki/Determination_of...

    For example, with pH titration data, if pH is measured to 2 decimal places, the errors of log 10 β should not be much larger than 0.01. In exploratory work where the nature of the species present is not known in advance, several different chemical models may be tested and compared.

  9. pH - Wikipedia

    en.wikipedia.org/wiki/PH

    The pH scale is traceable to a set of standard solutions whose pH is established by international agreement. [3] Primary pH standard values are determined using a concentration cell with transference by measuring the potential difference between a hydrogen electrode and a standard electrode such as the silver chloride electrode.