A weighting curve is a graph of a set of factors, that are used to 'weight' measured values of a variable according to their importance in relation to some outcome. An important example is frequency weighting in sound level measurement where a specific set of weighting curves known as A-, B-, C-, and D-weighting as defined in IEC 61672 [1] are used.
This led to the CCIR-468 standard which defined a new weighting curve and quasi-peak rectifier. The origin of the current ITU-R 468 weighting curve can be traced to 1956. The 1968 BBC EL-17 report discusses several weighting curves, including one identified as D.P.B. which was chosen as superior to the alternatives: A.S.A, C.C.I.F and O.I.R.T ...
A graph of the A-, B-, C- and D-weightings across the frequency range 10 Hz – 20 kHz Video illustrating A-weighting by analyzing a sine sweep (contains audio). A-weighting is a form of frequency weighting and the most commonly used of a family of curves defined in the International standard IEC 61672:2003 and various national standards relating to the measurement of sound pressure level. [1]
A commonly used weighting is the A-weighting curve, which results in units of dBA sound pressure level. Because the frequency response of human hearing varies with loudness, the A-weighting curve is correct only at a level of 40- phon and other curves known as B- , C- and D-weighting are also used, the latter being particularly intended for the ...
The report states that it is fortunate that the 40-phon Fletcher–Munson curve on which the A-weighting standard was based turns out to have been in agreement with modern determinations. [4] The report also comments on the large differences apparent in the low-frequency region, which remain unexplained. Possible explanations are: [4]
A weighted curves follow a 40 phon curve while C weighted follows a 100 phon curve. [4] The three curves differ not in their measurement of exposure levels, but in the frequencies measured. A weighted curves allow more frequencies equal to or less than 500 Hz through, which is most representative of the human ear. [4]
The ITU-R 468 noise weighting was devised specifically for this purpose, and is widely used in broadcasting, especially in the UK and Europe. A-weighting is also used, especially in the United States, [1] [dubious – discuss] though this is only really valid for the measurement of tones, not noise, and is widely incorporated into sound level ...
The proper measurement of noise, therefore, requires the use of a specified method, with defined measurement bandwidth and weighting curve, and rectifier dynamics. The two main methods defined by current standards are A-weighting and ITU-R 468 (formerly known as CCIR weighting).