In practice, creep during drying is inseparable from shrinkage. The rate of creep increases with the rate of change of pore humidity (i.e., relative vapor pressure in the pores). For small specimen thickness, the creep during drying greatly exceeds the sum of the drying shrinkage at no load and the creep of a loaded sealed specimen (Fig. 1 bottom).
Concrete has a very low coefficient of thermal expansion, and as it matures concrete shrinks. All concrete structures will crack to some extent, due to shrinkage and tension. Concrete which is subjected to long-duration forces is prone to creep. The density of concrete varies, but is around 2,400 kilograms per cubic metre (150 lb/cu ft). [1]
The creep of concrete, which originates from the calcium silicate hydrates (C-S-H) in the hardened Portland cement paste (which is the binder of mineral aggregates), is fundamentally different from the creep of metals as well as polymers. Unlike the creep of metals, it occurs at all stress levels and, within the service stress range, is ...
Dead loads have small load factors, such as 1.2, because weight is mostly known and accounted for, such as structural members, architectural elements and finishes, large pieces of mechanical, electrical and plumbing (MEP) equipment, and for buildings, it's common to include a Super Imposed Dead Load (SIDL) of around 5 pounds per square foot ...
The loss of force in a prestressing tendon that occurs over time as the result of shrinkage, creep and relaxation actions. [1]: 68 [3]: 14 transfer length The distance required to fully transfer the bonded tendon's prestressing force to the surrounding concrete solely by bond. [4]: 268 transfer strength
Degraded concrete and rusted, exposed reinforcement bar (rebar) on Welland River bridge of the Queen Elizabeth Way in Niagara Falls, Ontario. Concrete degradation may have many different causes. Concrete is mostly damaged by the corrosion of reinforcement bars due to the carbonatation of hardened cement paste or chloride attack under wet ...
Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.
Engineers often use this calculation in tensile tests. The area under this elastic region is known as resilience. Note that not all elastic materials undergo linear elastic deformation; some, such as concrete, gray cast iron, and many polymers, respond in a nonlinear fashion. For these materials Hooke's law is inapplicable.