enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    A standard 12-lead ECG report (an electrocardiograph) shows a 2.5 second tracing of each of the twelve leads. The tracings are most commonly arranged in a grid of four columns and three rows. The first column is the limb leads (I, II, and III), the second column is the augmented limb leads (aVR, aVL, and aVF), and the last two columns are the ...

  3. Rhythm interpretation - Wikipedia

    en.wikipedia.org/wiki/Rhythm_interpretation

    There are 6 different sinus arrhythmia. [1] [2]A normal heart should have a normal sinus rhythm, this rhythm can be identified by a ventricular rate of 60-100 bpm, at a regular rate, with a normal PR interval (0.12 to 0.20 second) and a normal QRS complex (0.12 second and less).

  4. Ventricular fibrillation - Wikipedia

    en.wikipedia.org/wiki/Ventricular_fibrillation

    Fine ventricular fibrillation as seen on a rhythm strip [13] Ultrasound confirmation of above rhythm strip [13] Log-log graph of the effect of alternating current I of duration T passing from left hand to feet as defined in IEC publication 60479–1. [14] AC-1: imperceptible AC-2: perceptible but no muscle reaction

  5. Wandering atrial pacemaker - Wikipedia

    en.wikipedia.org/wiki/Wandering_atrial_pacemaker

    Both arrhythmias have at least 3 different P-wave morphologies in a single ECG lead, but the heart rate is different. When the heart rate is lower than 100 beats per minute, the heart rhythm is considered wandering atrial pacemaker. When the heart rate is greater than 100 beats per minute, the heart rhythm is considered multifocal atrial ...

  6. Right bundle branch block - Wikipedia

    en.wikipedia.org/wiki/Right_bundle_branch_block

    The heart rhythm must originate above the ventricles (i.e., sinoatrial node, atria or atrioventricular node) to activate the conduction system at the correct point. The QRS duration must be more than 100 ms (incomplete block) or more than 120 ms (complete block). [9]

  7. Sinus tachycardia - Wikipedia

    en.wikipedia.org/wiki/Sinus_tachycardia

    Sinus tachycardia is a sinus rhythm of the heart, with an increased rate of electrical discharge from the sinoatrial node, resulting in a tachycardia, a heart rate that is higher than the upper limit of normal (90-100 beats per minute for adult humans). [1] The normal resting heart rate is 60–90 bpm in an average adult. [2]

  8. Third-degree atrioventricular block - Wikipedia

    en.wikipedia.org/wiki/Third-degree_atrio...

    This is known as an escape rhythm. Since this accessory pacemaker also activates independently of the impulse generated at the SA node, two independent rhythms can be noted on the electrocardiogram (ECG). The P waves with a regular P-to-P interval (in other words, a sinus rhythm) represent the first rhythm.

  9. Multifocal atrial tachycardia - Wikipedia

    en.wikipedia.org/wiki/Multifocal_atrial_tachycardia

    Multifocal atrial tachycardia is characterized by an electrocardiogram (ECG) strip with three or more discrete P wave morphologies in the same lead, not including that originating from the sinoatrial node, plus tachycardia, which is a heart rate exceeding 100 beats per minute (although some suggest using a threshold of 90 beats per minute ...