AEP meter label format follows ANSI C12.10 requirements for format of the electric meter labels. (See below) The format for the barcode label is: . AABYYYYYYYYYZZZZZ where AA is the meter test code B is an identifier for the meter manufacturer YYYYYYYYY is the manufacturer’s serial number or utility number ZZZZZ is user specified
IEC 62057-1 Electrical energy meters – Test equipment, techniques and procedures – Part 1: Stationary meter test units (MTUs) IEC 62057-3 Electrical energy meters – Test equipment, techniques and procedures – Part 3: Automatic meter testing system (AMTS) IEC 62058 Electricity metering equipment (AC) – Acceptance inspection
That same year, NETA released its first standard, Acceptance Testing Specifications for Electrical Power Equipment and Systems. NETA then turned its attention to improving the work of electrical technicians. To that end, the NETA Electrical Testing Technician Certification program was established in 1975.
ISO/IEC 17025 General requirements for the competence of testing and calibration laboratories is the main standard used by testing and calibration laboratories. In most countries, ISO/IEC 17025 is the standard for which most labs must hold accreditation in order to be deemed technically competent.
NABL Schemes include Accreditation (Recognition) of Technical competence of testing, calibration, medical testing laboratories, Proficiency testing providers (PTP) & Reference Material Producers (RMP) for a specific scope following ISO/IEC 17025, ISO 15189, ISO/IEC 17043 [2] & ISO 17034:2016 [3] Standards.
Guidance is provided by the IET in the form of the Code of Practice for In-service Inspection and Testing of Electrical Equipment – 5th Edition published in October 2021. [ 15 ] In Australia it is a legal requirement, per AS/NZS 3760 2010, that formal PAT testing ( Test and Tag ) is performed by a competent person, with suitable competence ...
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
It necessitates the test of surge immunity in electrical or electronic equipment. IEC 61000-4-5 defines test set-up, procedures, and classification levels. In particular, it standardizes the required surge voltage and current waveforms for laboratory testing, with the "1.2/50-8/20 μs" impulse being the most frequently used surge waveform.