Search results
Results from the WOW.Com Content Network
As polarised light passes through a birefringent sample, the phase difference between the fast and slow directions varies with the thickness, and wavelength of light used. The optical path difference (o.p.d.) is defined as o . p . d . = Δ n ⋅ t {\displaystyle {o.p.d.}=\Delta \,n\cdot t} , where t is the thickness of the sample.
In optical mineralogy, a petrographic microscope and cross-polarised light are often used to view the interference pattern. The thin section containing the mineral to be investigated is placed on the microscope stage, above one linear polariser, but with a second (the "analyser") between the objective lens and the eyepiece.
The optical microscope, also referred to as a light microscope, is a type of microscope that commonly uses visible light and a system of lenses to generate magnified images of small objects. Optical microscopes are the oldest design of microscope and were possibly invented in their present compound form in the 17th century.
The standardized model of the eye's response to light as a function of wavelength is given by the luminosity function. The eye has different responses as a function of wavelength when it is adapted to light conditions ( photopic vision ) and dark conditions ( scotopic vision ).
The figure shows the optical path of a Mirau-interferometer. Reference beam (5-4-6) and object beam (5-7-6) have identical optical path length and can thus cause white light interference. Parts of the Mirau interferometer: 1. Lens of the microscope, 2. Semitransparent mirror, 3. Object surface, 4. Reference mirror with reference beam, 5.
A total internal reflection fluorescence microscope (TIRFM) is a type of microscope with which a thin region of a specimen, usually less than 200 nanometers can be observed. TIRFM is an imaging modality which uses the excitation of fluorescent cells in a thin optical specimen section that is supported on a glass slide.
The optics do not change the color of the specimen, making it easy to interpret what is observed. Bright-field microscopy is a standard light-microscopy technique, and therefore magnification is limited by the resolving power possible with the wavelength of visible light. The practical limit to magnification with a light microscope is around ...
Microscope image processing is a broad term that covers the use of digital image processing techniques to process, analyze and present images obtained from a microscope. Such processing is now commonplace in a number of diverse fields such as medicine , biological research , cancer research , drug testing , metallurgy , etc.