The treatment of boiler water can be put into two parts. These are internal treatment and external treatment. (Sendelbach, p. 131) [4] The internal treatment is for boiler feed water and external treatment is for make-up feed water and the condensate part of the system. Internal treatment protects against feed water hardness by preventing ...
Manufacturing process wastestreams, which can include conventional pollutants (i.e. controllable with secondary treatment systems), toxic pollutants (e.g. solvents, heavy metals), and other harmful compounds such as nutrients; Non-process wastestreams: boiler blowdown and cooling water, which produce thermal pollution and other pollutants
A sectional diagram of a typical steam boiler feed injector, simplified to show the major parts common to such injectors, showing typical proportions, and using colour and shading to hint at temperature, pressure, and velocity variations in the fluid flows. The SVG was hand coded using a text editor.
Two of the main processes of industrial water treatment are boiler water treatment and cooling water treatment. A large amount of proper water treatment can lead to the reaction of solids and bacteria within pipe work and boiler housing. Steam boilers can suffer from scale or corrosion when left untreated. Scale deposits can lead to weak and ...
The feed water cycle begins with condensate water being pumped out of the condenser after traveling through the steam turbines. The condensate flow rate at full load in a 500 MW plant is about 6,000 US gallons per minute (400 L/s). Diagram of boiler feed water deaerator (with vertical, domed aeration section and horizontal water storage section).
The water may be freshly supplied or returning condensate produced as a result of the condensation of the steam produced by the boiler. These pumps are normally high pressure units that take suction from a condensate return system and can be of the centrifugal pump type or positive displacement type.
In a water tube boiler, the water is recirculated inside until the vapor pressure of the water overcomes the vapor pressure inside the stream drum and becomes saturated steam. The forced circulation boiler begins the same as a natural circulation boiler, at the feed water pump. Water is introduced into the steam drum and is circulated around ...
With oxygenated treatment, oxygen is injected into the feedwater to keep the oxygen level between 30 and 50 ppb. OT programs are most commonly used in supercritical (i.e. >3250psi) power boilers. The ability to change an existing sub-critical boiler over to an OT program is very limited.