  1. Results from the WOW.Com Content Network
  2. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    If this is the case, then the load banks used for testing require reactive power compensation. The ideal solution is a combination of both resistive and reactive elements in one load bank package. Resistive/reactive loads are able to mimic motor loads and electromagnetic devices within a power system, as well as provide purely resistive loads.

  3. Voltage control and reactive power management - Wikipedia

    en.wikipedia.org/wiki/Voltage_control_and...

    Since the reactive power does not travel over the wires as well as the real power, [19] there is an incentive to concentrate its production close to the load. Restructuring of electric power systems takes this area of the power grid out of hands of the integrated power utility , so the trend is to push the problem onto the customer and require ...

  4. Impedance matching - Wikipedia

    en.wikipedia.org/wiki/Impedance_matching

    For example, in order to match an inductive load into a real impedance, a capacitor needs to be used. If the load impedance becomes capacitive, the matching element must be replaced by an inductor. In many cases, there is a need to use the same circuit to match a broad range of load impedance and thus simplify the circuit design.

  5. Volt-ampere - Wikipedia

    en.wikipedia.org/wiki/Volt-ampere

    With a purely resistive load, they are the same: the apparent power is equal to the real power. Where a reactive (capacitive or inductive) component is present in the load, the apparent power is greater than the real power as voltage and current are no longer in phase.

  6. Maximum power transfer theorem - Wikipedia

    en.wikipedia.org/wiki/Maximum_power_transfer_theorem

    A refinement of the maximum power theorem says that any reactive components of source and load should be of equal magnitude but opposite sign. (See below for a derivation.) This means that the source and load impedances should be complex conjugates of each other. In the case of purely resistive circuits, the two concepts are identical.

  7. Voltage optimisation - Wikipedia

    en.wikipedia.org/wiki/Voltage_optimisation

    Voltage optimisation is a term given to the systematic controlled reduction in the voltages received by an energy consumer to reduce energy use, power demand and reactive power demand. While some voltage 'optimisation' devices have a fixed voltage adjustment, others electronically regulate the voltage automatically.

  8. AC power - Wikipedia

    en.wikipedia.org/wiki/AC_power

    Voltage levels and reactive power flow must be carefully controlled to allow a power system to be operated within acceptable limits. A technique known as reactive compensation is used to reduce apparent power flow to a load by reducing reactive power supplied from transmission lines and providing it locally. For example, to compensate an ...

  9. Leading and lagging current - Wikipedia

    en.wikipedia.org/wiki/Leading_and_Lagging_Current

    This generally occurs when the load drawing the current is resistive. In electric power flow, it is important to know how much current is leading or lagging because it creates the reactive power in the system, as opposed to the active (real) power. It can also play an important role in the operation of three phase electric power systems.