enow.com Web Search

  1. Ads

    related to: anode stuck in water heater pipe fittings removal procedure problems and solutions

Search results

  1. Results from the WOW.Com Content Network
  2. Erosion corrosion of copper water tubes - Wikipedia

    en.wikipedia.org/wiki/Erosion_corrosion_of...

    The actual attack on the metal is by the corrosive action of the water to which it is exposed while the erosive factor is the mechanical removal of the corrosion product from the surface. Impingement attack produces highly characteristic water-swept pits, which are often horseshoe shaped, or it can produce broader areas of attack.

  3. Heat trap - Wikipedia

    en.wikipedia.org/wiki/Heat_trap

    Heat traps are valves or loops of pipe on the cold water inlet and hot water outlet of water heaters. The heat traps allow cold water to flow into the water heater tank, but prevent unwanted natural convection and heated water to flow out of the tank. [1] [2] Newer water heaters have built-in heat traps.

  4. Cathodic protection - Wikipedia

    en.wikipedia.org/wiki/Cathodic_protection

    Over time the galvanic anode continues to corrode, consuming the anode material until eventually it must be replaced. Galvanic or sacrificial anodes are made in various shapes and sizes using alloys of zinc, magnesium, and aluminum. ASTM International publishes standards on the composition and manufacturing of galvanic anodes. [10] [11] [12]

  5. Galvanic anode - Wikipedia

    en.wikipedia.org/wiki/Galvanic_anode

    In brief, corrosion is a chemical reaction occurring by an electrochemical mechanism (a redox reaction). [1] During corrosion of iron or steel there are two reactions, oxidation (equation 1), where electrons leave the metal (and the metal dissolves, i.e. actual loss of metal results) and reduction, where the electrons are used to convert oxygen and water to hydroxide ions (equation 2): [2]

  6. Cold water pitting of copper tube - Wikipedia

    en.wikipedia.org/wiki/Cold_water_pitting_of...

    In addition to being cold hard and organically pure, the water needs a specific chemistry. The effect of the water chemistry can be empirically determined though use of the Pitting Propensity Rating (PPR) a number that takes into account the sulfate, chloride, nitrate and sodium ion concentrations of the water as well as its acidity or pH. A ...

  7. Anodic protection - Wikipedia

    en.wikipedia.org/wiki/Anodic_protection

    Anodic protection (AP) otherwise referred to as Anodic Control is a technique to control the corrosion of a metal surface by making it the anode of an electrochemical cell and controlling the electrode potential in a zone where the metal is passive.

  8. Pipe recovery operations - Wikipedia

    en.wikipedia.org/wiki/Pipe_recovery_operations

    This results in costly downtime, ranging anywhere from $10,000-1,000,000 per day of downtime, therefore it is critical to resolve the problem as quickly as possible. Pipe recovery is the process by which the location of the stuck pipe is identified, and the free pipe is separated from the stuck pipe either by a backoff or a chemical cut.

  9. Galvanic corrosion - Wikipedia

    en.wikipedia.org/wiki/Galvanic_corrosion

    Another example is the cathodic protection of buried or submerged structures as well as hot water storage tanks. In this case, sacrificial anodes work as part of a galvanic couple, promoting corrosion of the anode, while protecting the cathode metal.

  1. Ads

    related to: anode stuck in water heater pipe fittings removal procedure problems and solutions
  1. Related searches anode stuck in water heater pipe fittings removal procedure problems and solutions

    what is a anodegalvanic anode die casting process