enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Indoor air quality - Wikipedia

    en.wikipedia.org/wiki/Indoor_air_quality

    Humans are the main indoor source of carbon dioxide (CO 2) in most buildings. Indoor CO 2 levels are an indicator of the adequacy of outdoor air ventilation relative to indoor occupant density and metabolic activity. Indoor CO 2 levels above 500 ppm can lead to higher blood pressure and heart rate, and increased peripheral blood circulation. [85]

  3. Demand controlled ventilation - Wikipedia

    en.wikipedia.org/wiki/Demand_controlled_ventilation

    As the sensor reads the increasing amount of carbon dioxide levels in a space, the ventilation increases to dilute the levels. When the space is unoccupied, the sensor reads normal levels, and continues to supply the unoccupied airflow rate. This rate is determined by the building owner standards, along with the designer and ASHRAE Standard 62. ...

  4. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    Ventilation guidelines are based on the minimum ventilation rate required to maintain acceptable levels of effluents. Carbon dioxide is used as a reference point, as it is the gas of highest emission at a relatively constant value of 0.005 L/s. The mass balance equation is: Q = G/(C i − C a) Q = ventilation rate (L/s) G = CO 2 generation rate

  5. ASHRAE 55 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_55

    ANSI/ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy is an American National Standard published by ASHRAE that establishes the ranges of indoor environmental conditions to achieve acceptable thermal comfort for occupants of buildings. It was first published in 1966, and since 2004 has been updated every three to six years.

  6. Air quality law - Wikipedia

    en.wikipedia.org/wiki/Air_quality_law

    Another set of standards, for indoor air in employment settings, is administered by the U.S. Occupational Safety and Health Administration. [7] A distinction may be made between mandatory and aspirational air quality standards. For example, U.S. state governments must work toward achieving NAAQS, but are not forced to meet them.

  7. Household air pollution - Wikipedia

    en.wikipedia.org/wiki/Household_air_pollution

    Indoor PM 2.5 exposure levels have been consistently reported to be in the range of hundreds to thousands of micrograms per cubic meter (μg/m 3). Similarly, CO exposure levels have been measured to be as high as hundreds to greater than 1000 milligrams per cubic meter (mg/m 3 ).

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour is a measurement intended to communicate the air change effectiveness of a space’s ventilation system. Discussion around the ASHRAE standard 62, Ventilation for Acceptable Indoor Air Quality led to the development of a more direct method of measuring air change effectiveness with the use of a tracer gas. [1]