enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Signal-to-noise ratio (imaging) - Wikipedia

    en.wikipedia.org/wiki/Signal-to-noise_ratio...

    SNR is sometimes quantified in decibels (dB) of signal power relative to noise power, though in the imaging field the concept of "power" is sometimes taken to be the power of a voltage signal proportional to optical power; so a 20 dB SNR may mean either 10:1 or 100:1 optical power, depending on which definition is in use.

  3. Signal-to-noise ratio - Wikipedia

    en.wikipedia.org/wiki/Signal-to-noise_ratio

    Signal-to-noise ratio (SNR or S/N) is a measure used in science and engineering that compares the level of a desired signal to the level of background noise. SNR is defined as the ratio of signal power to noise power , often expressed in decibels .

  4. Peak signal-to-noise ratio - Wikipedia

    en.wikipedia.org/wiki/Peak_signal-to-noise_ratio

    Peak signal-to-noise ratio (PSNR) is an engineering term for the ratio between the maximum possible power of a signal and the power of corrupting noise that affects the fidelity of its representation.

  5. Contrast-to-noise ratio - Wikipedia

    en.wikipedia.org/wiki/Contrast-to-noise_ratio

    Contrast-to-noise ratio (CNR) [1] is a measure used to determine image quality. CNR is similar to the metric signal-to-noise ratio (SNR), but subtracts a term before taking the ratio. This is important when there is a significant bias in an image, such as from haze. [ 2 ]

  6. Photon-counting computed tomography - Wikipedia

    en.wikipedia.org/wiki/Photon-counting_computed...

    With this lens, there are several potential advantages of using a PCD over using an EID in CT imaging. These include improved signal (and contrast) to noise ratio, reduced X-ray dose to the patient, improved spatial resolution and, through use of several energy bins, the ability to distinguish multiple contrast agents.

  7. Contrast resolution - Wikipedia

    en.wikipedia.org/wiki/Contrast_resolution

    Unlike most other imaging modalities, such as x-ray CT in which the Hounsfield units value for water is set to zero, there is no standard reference signal for MRI. Thus the contrast-to-noise ratio is often employed as an index for contrast because this metric does not require a reference signal.

  8. Signal averaging - Wikipedia

    en.wikipedia.org/wiki/Signal_averaging

    Signal averaging is a signal processing technique applied in the time domain, intended to increase the strength of a signal relative to noise that is obscuring it. By averaging a set of replicate measurements, the signal-to-noise ratio (SNR) will be increased, ideally in proportion to the square root of the number of measurements.

  9. Minimum detectable signal - Wikipedia

    en.wikipedia.org/wiki/Minimum_detectable_signal

    A minimum detectable signal is a signal at the input of a system whose power allows it to be detected over the background electronic noise of the detector system. It can alternately be defined as a signal that produces a signal-to-noise ratio of a given value m at the output. In practice, m is usually chosen to be greater than unity.