Search results
Results from the WOW.Com Content Network
A colorimeter is a device used to test the concentration of a solution by measuring its absorbance of a specific wavelength of light. To use this device, different solutions must be made, and a control (usually a mixture of distilled water and another solution) is first filled into a cuvette and placed inside a colorimeter to calibrate the machine.
His common-path interferometer design provided automatic compensation of path length, so that white light fringes were visible at once as soon as the optical elements were aligned. Topologically, the light path was that of a Sagnac interferometer with an even number of reflections in each light path.
The cuvette is filled with sample, light is passed through the sample and intensity readings are taken. The slope spectroscopy technique can be applied using the same methods as in absorption spectroscopy. With the advent of accurate linear stages, variable pathlength absorption spectroscopy is easily applied experimentally.
Light is reflected from the two mirrors back to the beam splitter and some fraction of the original light passes into the sample compartment. There, the light is focused on the sample. On leaving the sample compartment the light is refocused on to the detector. The difference in optical path length between the two arms to the interferometer is ...
Spectrophotometry is a tool that hinges on the quantitative analysis of molecules depending on how much light is absorbed by colored compounds. Important features of spectrophotometers are spectral bandwidth (the range of colors it can transmit through the test sample), the percentage of sample transmission, the logarithmic range of sample ...
c is a compensating plate so that both the reflected and transmitted beams travel through the same amount of glass (important since experiments were run with white light which has an extremely short coherence length requiring precise matching of optical path lengths for fringes to be visible; monochromatic sodium light was used only for initial ...
The optical path difference between the paths taken by two identical waves can then be used to find the phase change. Finally, using the phase change, the interference between the two waves can be calculated. Fermat's principle states that the path light takes between two points is the path that has the minimum optical path length.
Ray tracing of a beam of light passing through a medium with changing refractive index.The ray is advanced by a small amount, and then the direction is re-calculated. Ray tracing works by assuming that the particle or wave can be modeled as a large number of very narrow beams (), and that there exists some distance, possibly very small, over which such a ray is locally straight.