Brass-bodied float valve. An automatic bleeding valve or air release valve (ARV) is a plumbing valve used to automatically release trapped air from a heating system. Air, or other gas, may collect within plumbing. For water delivery systems to taps and basins, particularly with good main supply pressure, this air is usually flushed through with ...
The definition of a closed loop control system according to the British Standards Institution is "a control system possessing monitoring feedback, the deviation signal formed as a result of this feedback being used to control the action of a final control element in such a way as to tend to reduce the deviation to zero." [2]
The boiler will also fire (regardless of thermostat state) when the boiler water temperature goes below a range around the low limit, ensuring that the boiler water temperature remains above a certain point. The low limit is intended for tankless domestic hot water; it ensures that boiler water is always warm enough to heat the domestic hot water.
Valves and their types and identifications (e.g. isolation, shutoff, relief and safety valves, valve interlocks) Control inputs and outputs (sensors and final elements, interlocks) Miscellaneous - vents, drains, flanges, special fittings, sampling lines, reducers and swages; Interfaces for class changes; Computer control system
A control loop is the fundamental building block of control systems in general and industrial control systems in particular. It consists of the process sensor, the controller function, and the final control element (FCE) which controls the process necessary to automatically adjust the value of a measured process variable (PV) to equal the value of a desired set-point (SP).
A cascade filling system is a high-pressure gas cylinder storage system that is used for the refilling of smaller compressed gas cylinders. [ 1 ] [ 2 ] In some applications, each of the large cylinders is filled by a compressor , otherwise they may be filled remotely and replaced when the pressure is too low for effective transfer.
The most common final control element in the process control industries is the control valve. The control valve manipulates a flowing fluid, such as gas, steam, water, or chemical compounds, to compensate for the load disturbance and keep the regulated process variable as close as possible to the desired set point. [1]
OpenTherm (OT) is a standard communications protocol used in central heating systems for the communication between central heating appliances and a thermostatic controllers. [1] As a standard, OpenTherm is independent of any single manufacturer. A controller from one manufacturer can in principle be used to control a boiler from another ...