Search results
Results from the WOW.Com Content Network
High voltage interface relays, a.k.a., interface relays: [1] [2] or coupling relays or insulating interfaces [3] [4] is a special class of electrical relays designed to provide informational and electrical compatibility between functional components isolated from each other and not allowing for a direct connection due to a high difference of potentials.
A solid state relay (SSR) is an electronic switching device that switches on or off when an external voltage (AC or DC) is applied across its control terminals. They serve the same function as an electromechanical relay , but solid-state electronics contain no moving parts and have a longer operational lifetime.
A relay Electromechanical relay principle Electromechanical relay schematic showing a control coil, four pairs of normally open and one pair of normally closed contacts An automotive-style miniature relay with the dust cover taken off. A relay is an electrically operated switch. It consists of a set of input terminals for a single or multiple ...
Digital/numerical relays provide a front panel display, or display on a terminal through a communication interface. This is used to display relay settings and real-time current/voltage values, etc. More complex digital relays will have metering and communication protocol ports, allowing the relay to become an element in a SCADA system.
In many cases, it is possible to design a relay logic diagram directly from the narrative description of a control event sequence. In general, the following suggestions apply to designing a relay logic diagram: 1. Define the process to be controlled. 2. Draw a sketch of the operation process. Make sure all the components of the system are ...
Trackside functional modules (points module on left, signal module on right) Trackside equipment such as signals and points are connected to nearby 'trackside functional modules' (TFMs). Each module has a number of outputs and inputs. Each output drives an individual function, such as a signal lamp or an AWS inductor. Certain outputs are ...
The redundant design ensures that wiring errors do not lead to the loss of the safety function. Two relays (K1, K2) with positive-guided contacts provide the safe switching contacts. The two input circuits CH1 and CH2 each activate one of the two internal relays. The circuit is activated via the start relay K3.
Two coils on each crosspoint were wired in series with all the others on that level, to the P lead. Each output of the array also had a P lead with two coils on each crosspoint of that output level. The two windings controlled by the same level were unequal, and were wound around opposite ends of the reed, in opposing polarity.