enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Generator interlock kit - Wikipedia

    en.wikipedia.org/wiki/Generator_Interlock_Kit

    Early generator interlock kits consisted of two sliding steel or plastic (depending on the brand) plates held together by three bolts and installed on the front cover of the home's breaker panel, however, some models made by Eaton (formerly Cutler-Hammer) and Siemens for panels manufactured by them install on the adjacent circuit breakers themselves and consist of a sliding arm for breakers ...

  3. Three-prong adaptor - Wikipedia

    en.wikipedia.org/wiki/Three-prong_adaptor

    The ground tab is designed to be attached to the outlet faceplate screw, which is supposed to be connected to the building electrical ground. A cheater plug, AC ground lifter or three-prong/two-prong adapter is an adapter that allows a NEMA 5-15P grounding-type plug (three prongs) to connect to a NEMA 1-15R non-grounding receptacle (two slots).

  4. Ring ground - Wikipedia

    en.wikipedia.org/wiki/Ring_ground

    A halo ground is a type of ring ground that, instead of being installed outside and underground, is installed inside, near the top of a building or structure. The ...

  5. Overhead power line - Wikipedia

    en.wikipedia.org/wiki/Overhead_power_line

    The ground conductor is usually grounded (earthed) at the top of the supporting structure, to minimize the likelihood of direct lightning strikes to the phase conductors. [18] In circuits with earthed neutral, it also serves as a parallel path with the earth for fault currents. Very high-voltage transmission lines may have two ground conductors.

  6. Ground-level power supply - Wikipedia

    en.wikipedia.org/wiki/Ground-level_power_supply

    Seville Tram equipped with CAF ACR ground-level power supply, 2019. Ground-level power supply, also known as surface current collection or, in French, alimentation par le sol ("feeding via the ground"), is a concept and group of technologies that enable electric vehicles to collect electric power at ground level instead of the more common overhead lines.

  7. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    A ground fault protection relay must trip the breaker to protect the circuit before overheating of the resistor occurs. High-resistance grounding (HRG) systems use an NGR to limit the fault current to 25 A or less. They have a continuous rating, and are designed to operate with a single-ground fault.

  8. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    A ground connection that is missing or of inadequate capacity may not provide the protective functions as intended during a fault in the connected equipment. Extra connections between ground and circuit neutral may result in circulating current in the ground path, stray current introduced in the earth or in a structure, and stray voltage.

  9. Floating ground - Wikipedia

    en.wikipedia.org/wiki/Floating_ground

    Electrical equipment may be designed with a floating ground for one of several reasons. One is safety. For example, a low-voltage DC power supply, such as a mobile phone charger, is connected to the mains through a transformer of one type or another, and there is no direct electrical connection between the current return path on the low-voltage side and physical ground (earth).