Ad
related to: how to test psu power supply calculator newegg free
Search results
Results from the WOW.Com Content Network
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).
The line regulation for an unregulated power supply is usually very high for a majority of operations, but this can be improved by using a voltage regulator. A low line regulation is always preferred. In practice, a well regulated power supply should have a line regulation of at most 0.1%. [1]
For amplifiers with both positive and negative power supplies (with respect to earth, as op-amps often have), the PSRR for each supply voltage may be separately specified (sometimes written: PSRR+ and PSRR−), but normally the PSRR is tested with opposite polarity signals applied to both supply rails at the same time (otherwise the common-mode ...
The first IBM PC power supply unit (PSU) supplied two main voltages: +5 V and +12 V. It supplied two other voltages, −5 V and −12 V, but with limited amounts of power. Most microchips of the time operated on 5 V power. Of the 63.5 W these PSUs could deliver, most of it was on this +5 V rail.
The ATX specification defines the Power-Good signal as a +5-volt (V) signal generated in the power supply when it has passed its internal self-tests and the outputs have stabilized. This normally takes between 0.1 and 0.5 seconds after the power supply is switched on.
One of the issues with using an RC network to generate a PoR pulse is the sensitivity of the R and C values to the power-supply ramp characteristics. When the power supply ramp is rapid, the R and C values can be calculated so that the time to reach the switching threshold of the Schmitt trigger is enough to apply a long enough reset pulse ...
Power Distribution Network. The current path from the power supply through the PCB and IC package to the die (consumer) is called the power distribution network. Its role is to transfer the power to the consumers with little DC voltage drop, and to allow little ripple induced by dynamic current at the consumer (switching current).
When a company resells an OEM power supply under a new name, it must be certified under the new name and company, even if the OEM supply is certified. In some instances, a reseller has claimed a higher wattage than the supply can deliver, so the reseller's supply would not meet 80 Plus requirements.