enow.com Web Search

  1. Ads

    related to: furnace circulator pump not working on water heater motor control valve

Search results

  1. Results from the WOW.Com Content Network
  2. Circulator pump - Wikipedia

    en.wikipedia.org/wiki/Circulator_pump

    By installing a thermostatically controlled pump just after the farthest fixture on the loop, cyclic pumping maintains ready hot water up to the last fixture on the loop instead of wasting energy heating the piping from the last fixture to the water heater. Installing a circulation pump at the farthest fixture on a hot water circulation loop is ...

  3. Zone valve - Wikipedia

    en.wikipedia.org/wiki/Zone_valve

    Simple mechanical and control design ("SPST thermostats") Redundancy: If one zone pump fails, the others can remain working; Far superior method of linking multiple heat sources. Such as gas and solid fuel in one system. Disadvantages: Higher initial installation cost. Circulator pumps cost more than zone valves; Higher power consumption.

  4. Condensate pump - Wikipedia

    en.wikipedia.org/wiki/Condensate_pump

    Note also the 30' discharge valve and actuator to the left of the pump. - Lakeview Pumping Station, Clarendon and Montrose Avenues, Chicago, Cook County, IL} A condensate pump is a specific type of pump used to pump the condensate produced in an HVAC (heating or cooling), refrigeration, condensing boiler furnace, or steam system. [1]

  5. Control valve - Wikipedia

    en.wikipedia.org/wiki/Control_valve

    A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller. [1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure , temperature , and liquid level.

  6. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    The effects a variable flow system had on the selection of control valves, was not initially realized. A control valve was selected by using the same K v calculation, and the bypass on a 3-port valve blocked, giving a 2-port valve. It was not that simple. This is because our K v calculation K v = flow rate [m 3 /h] / ΔP [bar

  7. Central heating - Wikipedia

    en.wikipedia.org/wiki/Central_heating

    Circulating hot water can be used for central heating. Sometimes these systems are called hydronic heating systems. [22] Common components of a central heating system using water-circulation include: A supply of fuel, electric power or district heating supply lines; A boiler (or a heat exchanger for district heating) which heats water in the system

  8. Flow control valve - Wikipedia

    en.wikipedia.org/wiki/Flow_control_valve

    The most common final control element in the process control industries is the control valve. The control valve manipulates a flowing fluid, such as gas, steam, water, or chemical compounds, to compensate for the load disturbance and keep the regulated process variable as close as possible to the desired set point. [1]

  9. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    Hydronics (from Ancient Greek hydro- 'water') is the use of liquid water or gaseous water or a water solution (usually glycol with water) as a heat-transfer medium in heating and cooling systems. [ 1 ] [ 2 ] The name differentiates such systems from oil and refrigerant systems.

  1. Ads

    related to: furnace circulator pump not working on water heater motor control valve