Search results
Results from the WOW.Com Content Network
It facilitates a simple and quick assessment of the lateral chamber angle. The method involves a narrow slit of light from a slit lamp being projected onto the peripheral cornea at an angle of 60⁰ as near as possible to the limbus. The resulting image is a slit that is projected onto the surface of the cornea, the width is then used as a ...
In ophthalmology, gonioscopy is a routine procedure that measures the angle between the iris and the cornea (the iridocorneal angle), using a goniolens (also known as a gonioscope) together with a slit lamp or operating microscope. [1] [2] Its use is important in diagnosing and monitoring various eye conditions associated with glaucoma.
Eye examination with the aid of a slit lamp. Side view of a slit lamp machine. Cataract in human eye: magnified view seen on examination with the slit lamp. In ophthalmology and optometry, a slit lamp is an instrument consisting of a high-intensity light source that can be focused to shine a thin sheet of light into the eye.
Watzke-Allen test (WAT) also known as Watzke-Allen slit beam test (WASBT) is a test used in the diagnosis of a macular hole, a condition affecting the macular region in the retina of the eye. The test is done by projecting a thin line of light over the macula with a slit lamp .
used to check the power and axis of a cylindrical lens: Maddox rod: used to test for latent squint and retinal function Refraction box: has lenses of different powers for refraction testing: Slit lamp bio microscope: used for examining the anteriorly placed structures the eye; video link: Charts for vision - •Distant vision
The slit lamp also allows inspection of all the ocular media, from cornea to vitreous, plus magnified view of eyelids, and other external ocular related structures. Fluorescein staining of the tear film before slit lamp examination may reveal etiologies of the surface of the eye, such as corneal abrasions or keratitis due to herpes simplex ...
The optically active solution rotates the plane of polarization of the light emerging out of the polarizer P by some angle, so the light is transmitted by analyzer A and the field of view of the telescope becomes bright. Now the analyzer is rotated by a finite angle so that the field of view of the telescope again becomes dark.
OCT Biomicroscopy is the use of optical coherence tomography (OCT) in place of slit lamp biomicroscopy to examine the transparent axial tissues of the eye. [1] Traditionally, ophthalmic biomicroscopy has been completed with a slit lamp biomicroscope that uses slit beam illumination and an optical microscope to enable stereoscopic, magnified, cross-sectional views of transparent tissues in the ...