At the beginning of the flush cycle, as the water level in the toilet cistern tank drops, the flush valve flapper falls back to the bottom, stopping the main flow to the flush tube. Because the tank water level has yet to reach the fill line, water continues to flow from the tank and bowl fill tubes.
You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made.
Cistern in the Mission District, San Francisco, California. The Auxiliary Water Supply System (AWSS, though often referred to on manhole covers and hydrants as HPFS for High Pressure Fire System) is a high pressure water supply network built for the city of San Francisco in response to the failure of the existing emergency water system during the 1906 earthquake.
You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made.
Flush tanks or cisterns usually incorporate a mechanism to release water from the tank and an automatic valve to allow the cistern to be refilled automatically. This system is suitable for locations plumbed with 12.7 or 9.5 mm ( 1 ⁄ 2 or 3 ⁄ 8 inch) water pipes which cannot supply water quickly enough to flush the toilet; the tank is needed ...
An elevated water tank, also known as a water tower, will create a pressure at the ground-level outlet of 1 kPa per 10.2 centimetres (4.0 in) or 1 psi per 2.31 feet (0.70 m) of elevation. Thus a tank elevated to 20 metres creates about 200 kPa and a tank elevated to 70 feet creates about 30 psi of discharge pressure, sufficient for most ...
The water is typically pressurised by pumping the water into storage tanks constructed at the highest local point in the network. One network may have several such service reservoirs. In small domestic systems, the water may be pressurised by a pressure vessel or even by an underground cistern (the latter however does need additional pressurizing).
For this reason, the UK domestic water system has traditionally (prior to 1989) employed a "cistern feed" system, where the incoming supply is connected to the kitchen sink and also a header/storage tank in the attic. Water can dribble into this tank through a 12 mm pipe, plus ball valve, and then supply the house on 22 or 28 mm pipes.