The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.
The number of transfer units (NTU) method is used to calculate the rate of heat transfer in heat exchangers (especially parallel flow, counter current, and cross-flow exchangers) when there is insufficient information to calculate the log mean temperature difference (LMTD). Alternatively, this method is useful for determining the expected heat ...
Sol-air temperature (T sol-air) is a variable used to calculate cooling load of a building and determine the total heat gain through exterior surfaces. It is an improvement over: = Where: = rate of heat transfer [W] = heat transfer surface area [m 2]
12,000.00 Btu IT /h 2,593.90 ft⋅lbf/s A ton of refrigeration ( TR or TOR ), also called a refrigeration ton ( RT ), is a unit of power used in some countries (especially in North America) to describe the heat-extraction capacity of refrigeration and air conditioning equipment.
Btu per hour (Btu/h) is sometimes used in North America and the United Kingdom - the latter for air conditioning mainly, though "Btu/h" is sometimes abbreviated to just "Btu". [18] MBH—thousands of Btu per hour—is also common. [19] 1 W is approximately 3.412142 Btu/h [20] 1,000 Btu/h is approximately 0.2931 kW; 1 hp is approximately 2,544 Btu/h
A well designed ground source heat pump installation should achieve an SPF of 3.5, or over 5 if linked to a solar-assisted thermal bank. [6] Example: For a heat pump delivering 120,000,000 BTU during the season, when consuming 15,000 kWh, the HSPF can be calculated as : HSPF = 120000000 (BTU) / (1000) / 15000 (kWh) HSPF = 8
The temperature and humidity of air inside and outside the building are used in enthalpy calculations to determine when outside air can be used for free heating or cooling. Abbreviated OAT. packaged terminal air conditioner An air conditioner and heater combined into a single, electrically powered unit, typically installed through a wall and ...
As mentioned earlier in the article the convection heat transfer coefficient for each stream depends on the type of fluid, flow properties and temperature properties. Some typical heat transfer coefficients include: Air - h = 10 to 100 W/(m 2 K) Water - h = 500 to 10,000 W/(m 2 K).