    There are three main classifications of fire rated walls: fire walls, fire barriers, and fire partitions. A firewall is an assembly of materials used to delay the spread of fire a wall assembly with a prescribed fire resistance duration and independent structural stability. This allows a building to be subdivided into smaller sections.

  3. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    Canada de-rates closures, where, for instance a 2-hour closure is acceptable for use in a 3-hour fire separation, so long as the fire separation is not an occupancy separation or firewall. The lowered rating is then referred to as a fire protection rating, both for firestops, unless they contain plastic pipes and regular closures. Firestops

  4. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    This rating is the requirement for protecting paper documents. Above 350 °F (176.7 °C) paper is distorted by the heat and information is lost. A Class 350-4 Hour vault must keep the temperature below 350 °F. for at least four hours, with temperatures up to 2,000 °F. (1,093.3 °C) outside the vault.

  5. Fire door - Wikipedia

    en.wikipedia.org/wiki/Fire_door

    Fire-resistance rated door, with wire mesh glass vision panel Industrial grade fire door rated to hydrocarbon curve and blast resistance Double fire door immediately after 3-hour fire test inside a 4-hour rated Durasteel wall Double fire door after 3-hour fire test in a 4-hour Durasteel wall, during successful 45PSI (3.1 bar) hose stream test leading to a UL Listing [1]

  6. High-voltage transformer fire barriers - Wikipedia

    en.wikipedia.org/wiki/High-voltage_transformer...

    The primary North American document that deals with outdoor high-voltage transformer fire barriers is NFPA 850. [1] NFPA 850 outlines that outdoor oil-insulated transformers should be separated from adjacent structures and from each other by firewalls, spatial separation, or other approved means for the purpose of limiting the damage and potential spread of fire from a transformer failure.

  7. Occupancy - Wikipedia

    en.wikipedia.org/wiki/Occupancy

    For some high challenge occupancies, [4] the code requirements for an occupancy separation are more stringent than for other fire barriers, even with an identical fire resistance rating. In this case, an occupancy separation with a two-hour fire-resistance rating may not be able to "de-rate" its closures, such fire doors and firestops.

  8. LEGO Creators Show Off Their Most Interesting Builds, Here ...

    www.aol.com/80-coolest-most-majestic-lego...

    Image credits: Itsafiresale “Creating LEGO sets” is one of those jobs like astronaut or candy-taster that many kids would like to do at some point in their lives.

  9. List of fire-retardant materials - Wikipedia

    en.wikipedia.org/wiki/List_of_fire-retardant...

    Fire-retardant materials should not be confused with fire-resistant materials. A fire resistant material is one which is designed to resist burning and withstand heat. An example of a fire-resistant material is one which is used in bunker gear worn by firefighters to protect them from the flames of a burning building.