Congestive heart failure patients that were implanted with an ICD had an all-cause death risk 23% lower than placebo and an absolute decrease in mortality of 7.2 percentage points after five years in the overall population. 1 Reporting in 1999, the Antiarrhythmics Versus Implantable Defibrillators (AVID) trial consisted of 1,016 patients, and ...
Catheter ablation is a procedure that uses radio-frequency energy or other sources to terminate or modify a faulty electrical pathway from sections of the heart of those who are prone to developing cardiac arrhythmias such as atrial fibrillation, atrial flutter and Wolff-Parkinson-White syndrome.
The ULTRASEAL LAA device, from Cardia, is a percutaneous, transcatheter device intended to prevent thrombus embolization from the left atrial appendage in patients who have non-valvular atrial fibrillation. As with all Cardia devices (such as: Atrial Septal Defect Closure Device or Patent Foramen Ovale Closure Device), the Ultraseal is fully ...
The Cox maze procedure, also known as maze procedure, is a type of heart surgery for atrial fibrillation. "Maze" refers to the series of incisions arranged in a maze -like pattern in the atria . Today, various methods of minimally invasive maze procedures, collectively named minimaze procedures , are used.
Radiofrequency ablation (RFA), also called fulguration, [1] is a medical procedure in which part of the electrical conduction system of the heart, tumor, sensory nerves or a dysfunctional tissue is ablated using the heat generated from medium frequency alternating current (in the range of 350–500 kHz).
The ICD-10 Procedure Coding System (ICD-10-PCS) is a US system of medical classification used for procedural coding.The Centers for Medicare and Medicaid Services, the agency responsible for maintaining the inpatient procedure code set in the U.S., contracted with 3M Health Information Systems in 1995 to design and then develop a procedure classification system to replace Volume 3 of ICD-9-CM.
The magnet can interrupt the pacing and inhibit the output of pacemakers. If MRI must be done, the pacemaker output in some models can be reprogrammed. [7] In February 2011, the FDA approved an MRI-safe pacemaker. [8] Extracorporeal shock-wave lithotripsy (ESWL) procedure is safe for most pacemaker patients, with some reprogramming of the pacing.
This trial found that ILR screening led to a threefold increase in atrial fibrillation detection and anticoagulation initiation. However, it did not show a significant reduction in the risk of stroke or systemic arterial embolism, indicating that not all screen-detected atrial fibrillation might warrant anticoagulation treatment.