Search results
Results from the WOW.Com Content Network
An example is a coffee-cup calorimeter, which is constructed from two nested Styrofoam cups, providing insulation from the surroundings, and a lid with two holes, allowing insertion of a thermometer and a stirring rod. The inner cup holds a known amount of a solvent, usually water, that absorbs the heat from the reaction.
Constant-temperature calorimeter, phase change calorimeter for example an ice calorimeter or any other calorimeter observing a phase change or using a gauged phase change for heat measurement. Constant-volume calorimeter, also called bomb calorimeter; Constant-pressure calorimeter, enthalpy-meter, or coffee cup calorimeter
Systematic errors are errors that are not determined by chance but are introduced by repeatable processes inherent to the system. [5] Sources of systematic errors include errors in equipment calibration, uncertainty in correction terms applied during experimental analysis, errors due the use of approximate theoretical models.
Such errors are considered different than errors caused by different reasons; errors made during measurement reading, errors caused by human errors, and errors caused by a change in the measurement environment caused by the presence of the instrument affecting the environment.
Calorimetry requires that a reference material that changes temperature have known definite thermal constitutive properties. The classical rule, recognized by Clausius and Kelvin, is that the pressure exerted by the calorimetric material is fully and rapidly determined solely by its temperature and volume; this rule is for changes that do not involve phase change, such as melting of ice.
In metrology, measurement uncertainty is the expression of the statistical dispersion of the values attributed to a quantity measured on an interval or ratio scale.. All measurements are subject to uncertainty and a measurement result is complete only when it is accompanied by a statement of the associated uncertainty, such as the standard deviation.
a Calorimeter in CERN. In experimental particle physics, a calorimeter is a type of detector that measures the energy of particles. Particles enter the calorimeter and initiate a particle shower in which their energy is deposited in the calorimeter, collected, and measured. The energy may be measured in its entirety, requiring total containment ...
Systematic errors in the measurement of experimental quantities leads to bias in the derived quantity, the magnitude of which is calculated using Eq(6) or Eq(7). However, there is also a more subtle form of bias that can occur even if the input, measured, quantities are unbiased; all terms after the first in Eq(14) represent this bias.