enow.com Web Search

  1. Ad

    related to: hankison condensate drain valve problems water level 2 service

Search results

  1. Results from the WOW.Com Content Network
  2. Condensate pump - Wikipedia

    en.wikipedia.org/wiki/Condensate_pump

    The output of small condensate pumps is usually routed to a sewer, plumbing drain, or the outside world via PVC plastic tubing (condensate drain line). In some locales, condensate water is not permitted to enter a sewer system and must be directed to the outside of the house, usually into the leader/gutter downspout system, or the stormwater ...

  3. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    A sewer pipe is normally at neutral air pressure compared to the surrounding atmosphere.When a column of waste water flows through a pipe, it compresses air ahead of it in the system, creating a positive pressure that must be released so it does not push back on the waste stream and downstream traps, slow drainage, and induce potential clogs.

  4. Boiler blowdown - Wikipedia

    en.wikipedia.org/wiki/Boiler_blowdown

    A pipe near the bottom of the blowoff tank maintains a water level below the blowdown entry point and allows cooler water remaining from earlier blowdown events to drain from the tank first. Two bottom blowdown valves are often used in series to minimize erosion. One valve serves as the sealing valve, and the other as the blowdown valve.

  5. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices , [ 1 ] [ 2 ] reduced pressure zone assemblies (RPZA), [ 3 ] or reduced pressure ...

  6. Condensing boiler - Wikipedia

    en.wikipedia.org/wiki/Condensing_boiler

    Condensing boilers are water heaters typically used for heating systems that are fueled by gas or oil. When operated in the correct circumstances, a heating system can achieve high efficiency (greater than 90% on the higher heating value) by condensing water vapour found in the exhaust gases in a heat exchanger to preheat the circulating water.

  7. Deaerator - Wikipedia

    en.wikipedia.org/wiki/Deaerator

    If this vent valve has not be opened sufficiently, the deaerator will not work properly, resulting in feed water with a high oxygen content going to the boilers. Should the boiler not have an oxygen-content analyzer, a high level in the boiler chlorides may indicate the vent valve not being far enough open.

  8. Isolation valve - Wikipedia

    en.wikipedia.org/wiki/Isolation_valve

    Isolation valves in a flare, relief or vent system must ensure that a flow path is always available to the flare or vent. These valves are secured in the open position (LO). Drain valves that connect a high pressure system to a low pressure drain system are locked in the closed position (LC) to prevent potential over-pressurisation of the drain ...

  9. Boiler feedwater - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater

    Boiler feedwater is the water which is supplied to a boiler. The feed water is put into the steam drum from a feed pump. In the steam drum the feed water is then turned into steam from the heat. After the steam is used, it is then dumped to the main condenser. From the condenser, it is then pumped to the deaerated feed tank.

  1. Ad

    related to: hankison condensate drain valve problems water level 2 service