The SI unit of conductivity is S/m, and unless otherwise qualified, it refers to 25 °C. More generally encountered is the traditional unit of μS/cm. The commonly used standard cell has a width of 1 cm [clarify], and thus for very pure water in equilibrium with air would have a resistance of about 10 6 ohms, known as a megohm.
Electrical conductivity of water samples is used as an indicator of how salt-free, ion-free, or impurity-free the sample is; the purer the water, the lower the conductivity (the higher the resistivity). Conductivity measurements in water are often reported as specific conductance, relative to the conductivity of pure water at 25 °C.
The standard is most often used as a comparative property in the specification of the conductivity of other metals. For example, the conductivity of a particular grade of titanium may be specified as 1.2 % IACS, meaning that its electrical conductivity is 1.2 % of the copper specified as the IACS standard. [2]
The siemens (symbol: S) is the unit of electric conductance, electric susceptance, and electric admittance in the International System of Units (SI). Conductance, susceptance, and admittance are the reciprocals of resistance, reactance, and impedance respectively; hence one siemens is equal to the reciprocal of one ohm (Ω −1) and is also referred to as the mho.
Electrical conductivity: σ: Measure of a material's ability to conduct an electric current S/m L −3 M −1 T 3 I 2: scalar Electric potential: φ: Energy required to move a unit charge through an electric field from a reference point volt (V = J/C) L 2 M T −3 I −1: extensive, scalar Electrical resistance: R: Electric potential per unit ...
*The report in the Data Series says that the Taylor I laminate had a thermal conductivity of 0.0996 w cm −1 K −1 at 100 psi in descent and that is an obvious typo [NA]. What would fit is 0.00996 w cm −1 K −1 = 0.996 w m −1 K −1. TPRC Volume 2, pp 1037–9. Lead, pure
The Bresle method uses the difference of conductivity of salts in water, each salt having a characteristic conductivity-versus-concentration relationship. The correlation between concentration and conductivity can be found in "Handbook of Chemistry and Physics". This relationship is useful only if the dissolved salt is known.
Ground conductivity is an extremely important factor in determining the field strength and propagation of surface wave (ground wave) radio transmissions. Low frequency (30–300 kHz) and medium frequency (300–3000 kHz) radio transmissions are particularly reliant on good ground conductivity as their primary propagation is by surface wave. [1]