Search results
Results from the WOW.Com Content Network
The IEEE 693: Recommended Practice for Seismic Design of Substations. [ 1 ] is a Institute of Electrical and Electronics Engineers standard. This standard is recognized also by American National Standards Institute , and is used mainly in the American Continent.
Load-flow calculation is also the basis of all further network studies, such as motor start-up or investigation of scheduled or unscheduled outages of equipment within the outage simulation. Especially when investigating motor start-up, [ 2 ] the load-flow calculation results give helpful hints, for example, of whether the motor can be started ...
A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.
Analysis software for lightning protection used on a power substation. Power engineering software is a software used to create models, analyze or calculate the design of Power stations, Overhead power lines, Transmission towers, Electrical grids, Grounding and Lightning [clarification needed] systems and others. It is a type of application ...
IEC 61850 is an international standard defining communication protocols for intelligent electronic devices at electrical substations.It is a part of the International Electrotechnical Commission's (IEC) Technical Committee 57 reference architecture for electric power systems. [1]
The design stage, in which an electric systems model is created, and; The simulation or analysis stage, in which software simulation programs are used to test the integrity of the design; these simulation programs test how the model would behave in real-world operation by checking for specific types of design or operational problems (see list ...
For example, a long feeder with a high concentration of DG at the end will experience significant current injection at points where the voltage is normally lowest. If the load is sufficiently low, current will flow in the reverse direction (i.e. towards the substation), resulting in a voltage profile that increases with distance from the ...
Substation near Denver International Airport IEEE-1613 is the IEEE standard detailing environmental and testing requirements for communications networking devices in electric power substations . The standard is sponsored by the IEEE Power & Energy Society .