Nameplate capacity, also known as the rated capacity, nominal capacity, installed capacity, maximum effect or gross capacity, [1] is the intended full-load sustained output of a facility such as a power station, [2] [3] electric generator, a chemical plant, [4] fuel plant, mine, [5] metal refinery, [6] and many others. Nameplate capacity is the ...
Control of small electromagnetic loads with holding current ≤ 0.2 A; e.g. contactor relays 60947-5-2 A: Protection of circuits, with no rated short-time withstand current: 60947-3 B: Protection of circuits, with a rated short-time withstand current: 60947-3 DC-1: Non Inductive or slightly inductive loads, resistance furnaces, heaters: 60947-4 ...
For an electric machine, the power rating is the number on its rating plate and corresponds to a maximum electric load it can carry. There is a distinction between the continuous rating (for generators, continuous maximum rating or CMR [ 2 ] ), at which the machine can be operational without a time limit and short-term rating that can only be ...
Inrush current, input surge current, or switch-on surge is the maximal instantaneous input current drawn by an electrical device when first turned on. Alternating-current electric motors and transformers may draw several times their normal full-load current when first energized, for a few cycles of the input waveform.
For AC-operated devices (e.g. coaxial cable, loudspeakers), there may even be two power ratings, a maximum (peak) power rating and an average power rating. [ 5 ] [ 6 ] For such devices, the peak power rating usually specifies the low frequency or pulse energy, while the average power rating limits high-frequency operation. [ 5 ]
The burden (load) impedance should not exceed the specified maximum value to avoid the secondary voltage exceeding the limits for the current transformer. The primary current rating of a current transformer should not be exceeded, or the core may enter its non-linear region and ultimately saturate. This would occur near the end of the first ...
NEMA (National Electrical Manufacturers Association) contactors and motor starters are rated by sizes. These sizes are grouped by rated current and power. [1] [2]
As an example, consider the use of a 10 hp, 1760 r/min, 440 V, three-phase induction motor (a.k.a. induction electrical machine in an asynchronous generator regime) as asynchronous generator. The full-load current of the motor is 10 A and the full-load power factor is 0.8. Required capacitance per phase if capacitors are connected in delta: