Search results
Results from the WOW.Com Content Network
Motor capacitors are used with single-phase electric motors [3]: 11 that are in turn used to drive air conditioners, hot tub/jacuzzi spa pumps, powered gates, large fans or forced-air heat furnaces for example. [1] A "dual run capacitor" is used in some air conditioner compressor units, to boost both the fan and compressor motors. [1] Permanent ...
1A1A44J5 - Unit 1, Assembly 1, Sub-Assembly 44, Jack 5 (J5 is a connector on a box referenced as A44) 1A1A45J333 - Unit 1, Assembly 1, Sub-Assembly 45, Jack 333 (J333 is a connector on a box referenced as A45) A cable connecting these two might be: 1A1W35 - In the assembly A1 is a cable called W35. Connectors on this cable would be designated:
Structurally, capacitors consist of electrodes separated by a dielectric, connecting leads, and housing; deterioration of any of these may cause parameter shifts or failure. Shorted failures and leakage due to increase of parallel parasitic resistance are the most common failure modes of capacitors, followed by open failures.
A discharged or partially charged capacitor appears as a short circuit to the source when the source voltage is higher than the potential of the capacitor. A fully discharged capacitor will take approximately 5 RC time periods to fully charge; during the charging period, instantaneous current can exceed steady-state current by a substantial ...
Comparison of normal and distorted airflow into the compressor section [1] A compressor stall is a local disruption of the airflow in the compressor of a gas turbine or turbocharger. A stall that results in the complete disruption of the airflow through the compressor is referred to as a compressor surge. The severity of the phenomenon ranges ...
Failed aluminium electrolytic capacitors with open vents in the top of the can, and visible dried electrolyte residue (reddish-brown color) The capacitor plague was a problem related to a higher-than-expected failure rate of non-solid aluminium electrolytic capacitors between 1999 and 2007, especially those from some Taiwanese manufacturers, [1] [2] due to faulty electrolyte composition that ...
The position of the contact breaker is set so that it opens (and hence generates a spark) at exactly the optimum moment to ignite the fuel/air mixture. This point is generally just before the piston reaches the top of its compression stroke. The contact breaker is often mounted on a plate that is able to rotate relative to the camshaft ...
A rupture disc (burst) Pressure-effect acting at a rupture disc A rupture disc, also known as a pressure safety disc, burst disc, bursting disc, or burst diaphragm, is a non-reclosing pressure relief safety device that, in most uses, protects a pressure vessel, equipment or system from overpressurization or potentially damaging vacuum conditions.