enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    Power factor correcting capacitors can be added externally to neutralize a constant amount of the variable reactive excitation current. After starting, an induction generator can use a capacitor bank to produce reactive excitation current, but the isolated power system's voltage and frequency are not self-regulating and destabilize readily.

  3. Voltage control and reactive power management - Wikipedia

    en.wikipedia.org/wiki/Voltage_control_and...

    The amount of reactive power supplied by a shunt capacitor is proportional to the square of the line voltage, so the capacitor contributes less under low-voltage conditions (frequently caused by the lack of reactive power). This is a serious drawback, as the supply of reactive power by a capacitor drops when it is most needed; [11]

  4. AC power - Wikipedia

    en.wikipedia.org/wiki/AC_power

    Reactive power does not do any work, so it is represented as the imaginary axis of the vector diagram. Active power does do work, so it is the real axis. The unit for power is the watt (symbol: W). Apparent power is often expressed in volt-amperes (VA) since it is the product of RMS voltage and RMS current. The unit for reactive power is var ...

  5. Ancillary services (electric power) - Wikipedia

    en.wikipedia.org/wiki/Ancillary_services...

    The term ancillary services is used to refer to a variety of operations beyond generation and transmission that are required to maintain grid stability and security. These services generally include active power control or frequency control and reactive power control or voltage control, on various timescales.

  6. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    In practice, the prime mover (a power source that drives the generator) is designed for less active power than the generator is capable of (due to the fact that in real life generator always has to deliver some reactive power [2]), so a prime mover limit (a vertical dashed line on the illustration) changes the constraints somewhat (in the ...

  7. Slack bus - Wikipedia

    en.wikipedia.org/wiki/Slack_bus

    PQ bus – the real power |P| and reactive power |Q| are specified. It is also known as Load Bus. Generally, in a PQ bus, the generated real and reactive power will be assumed to be zero. However, power will be flowing out, thus, the real power and reactive power will be both negative. The Load Bus will be used to find the bus voltage and angle.

  8. Electric power transmission - Wikipedia

    en.wikipedia.org/wiki/Electric_power_transmission

    As reactive current increases, reactive power increases and power factor decreases. For transmission systems with low power factor, losses are higher than for systems with high power factor. Utilities add capacitor banks, reactors and other components (such as phase-shifters; static VAR compensators; and flexible AC transmission systems, FACTS ...

  9. Synchronous condenser - Wikipedia

    en.wikipedia.org/wiki/Synchronous_condenser

    The reactive power produced by a capacitor bank is in direct proportion to the square of its terminal voltage, and if the system voltage decreases, the capacitors produce less reactive power, when it is most needed, [2] while if the system voltage increases the capacitors produce more reactive power, which exacerbates the problem. In contrast ...