With oxygenated treatment, oxygen is injected into the feedwater to keep the oxygen level between 30 and 50 ppb. OT programs are most commonly used in supercritical (i.e. >3250psi) power boilers. The ability to change an existing sub-critical boiler over to an OT program is very limited.
The treatment of boiler water can be put into two parts. These are internal treatment and external treatment. (Sendelbach, p. 131) [4] The internal treatment is for boiler feed water and external treatment is for make-up feed water and the condensate part of the system. Internal treatment protects against feed water hardness by preventing ...
Boiler water treatment is a type of industrial water treatment focused on the removal or chemical modification of substances potentially damaging to the boiler. Varying types of treatment are used at different locations to avoid scale, corrosion, or foaming. [3] External treatment of raw water supplies intended for use within a boiler is ...
Two of the main processes of industrial water treatment are boiler water treatment and cooling water treatment. A large amount of proper water treatment can lead to the reaction of solids and bacteria within pipe work and boiler housing. Steam boilers can suffer from scale or corrosion when left untreated. Scale deposits can lead to weak and ...
The reduction of blowdown by dealkalization keeps the water treatment chemicals in the boiler longer, thus minimizing the amount of chemicals required for efficient, noncorrosive operation. [2] Carbonate and bicarbonate alkalinities are decomposed by heat in boiler water releasing carbon dioxide into the steam.
The treated water falls into a storage tank below the deaerator. [20] [3] Oxygen scavenging chemicals are very often added to the deaerated boiler feedwater to remove any last traces of oxygen that were not removed by the deaerator. The type of chemical added depends on whether the location uses a volatile or non-volatile water treatment program.
Scale deposition in boilers can reduce heat transfer efficiency and increase energy consumption. Antiscalants are added to boiler feedwater to prevent scale formation on heat transfer surfaces, piping, and other boiler components. Water treatment plants can use antiscalants to maintain filtration. [3]
Water is introduced into the steam drum and is circulated around the boiler, leaving only as steam. What makes the forced circulation boiler different is its use of a secondary pump that circulates water through the boiler. The secondary pump takes the feed water going to the boiler and raises the pressure of the water going in.