enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  3. Standard solution - Wikipedia

    en.wikipedia.org/wiki/Standard_solution

    Standard solutions are commonly used to determine the concentration of an analyte species via calibration curve. A calibration curve is obtained by measuring a series of standard solutions with known concentrations, which can be used to determine the concentration of an unknown sample using linear regression analysis. [10]

  4. Internal standard - Wikipedia

    en.wikipedia.org/wiki/Internal_standard

    The calibration curve that does not use the internal standard method ignores the uncertainty between measurements. The coefficient of determination (R 2) for this plot is 0.9985. In the calibration curve that uses the internal standard, the y-axis is the ratio of the nickel signal to the yttrium signal.

  5. Standard addition - Wikipedia

    en.wikipedia.org/wiki/Standard_addition

    In comparison to the calibration curve method, the standard addition method has the advantage of the matrices of the unknown and standards being nearly identical. [1] This minimizes the potential bias arising from the matrix effect when determining the concentration.

  6. Matrix (chemical analysis) - Wikipedia

    en.wikipedia.org/wiki/Matrix_(chemical_analysis)

    [3] [4] The most common approach for accounting for matrix effects is to build a calibration curve using standard samples with known analyte concentration and which try to approximate the matrix of the sample as much as possible. [2] This is especially important for solid samples where there is a strong matrix influence. [5]

  7. Laboratory quality control - Wikipedia

    en.wikipedia.org/wiki/Laboratory_quality_control

    A control chart is a more specific kind of run chart. The control chart is one of the seven basic tools of quality control, which also include the histogram, pareto chart, check sheet, cause and effect diagram, flowchart and scatter diagram. Control charts prevent unnecessary process adjustments, provide information about process capability ...

  8. Isotope dilution - Wikipedia

    en.wikipedia.org/wiki/Isotope_dilution

    Isotope dilution calibration plots sometimes show nonlinear relationships and in practice polynomial fitting is often performed to empirically describe such curves. [14] When calibration plots are markedly nonlinear, one can bypass the empirical polynomial fitting and employ the ratio of two linear functions (known as Padé approximant) which ...

  9. Karl Fischer titration - Wikipedia

    en.wikipedia.org/wiki/Karl_Fischer_titration

    The KF response is linear. Therefore, single-point calibration using a calibrated 1% water standard is sufficient and no calibration curves are necessary. Little sample preparation is needed: a liquid sample can usually be directly injected using a syringe. The analysis is typically complete within a minute.