Standards for validation and verification of medical laboratories are outlined in the international standard ISO 15189, in addition to national and regional regulations. [1] As per United States federal regulations, the following analytical tests need to be done by a medical laboratory that introduces a new testing device:
Verification is intended to check that a product, service, or system meets a set of design specifications. [6] [7] In the development phase, verification procedures involve performing special tests to model or simulate a portion, or the entirety, of a product, service, or system, then performing a review or analysis of the modeling results.
This article needs to be updated.The reason given is: the section related to E.U. needs further updates (esp. in sections 3.2 and 4.2.2) as the directives 93/42/EEC on medical devices and 90/385/EEC on active implantable medical devices have been fully repealed on 26 May 2021 by Regulation (EU) no. 2017/745 (MDR); furthermore, Brexit triggers updates in these sections (U.K. developed their own ...
The Medical Devices Directive (MDD 93/42/EEC) similarly lists several requirements regarding the design of a medical device. The Medical Devices Regulation (MDR (EU) 2017/745), replacing the MDD from 2021, requires information to allow the design stages applied to the device to be understood as part of the design and manufacturing information ...
Validation process efforts must account for the complete product life cycle, including developmental procedures adapted for qualification of a drug product commencing with its research and development phase, rationale for adapting a best fit formula which represents the relationship between required outputs and specified inputs, and procedure ...
ISO 13485 Medical devices -- Quality management systems -- Requirements for regulatory purposes is a voluntary standard, [1] published by International Organization for Standardization (ISO) for the first time in 1996, and contains a comprehensive quality management system for the design and manufacture of medical devices.
The guidance document "MEDDEV 2.12-1 rev 8" offers a comprehensive guidance on best practice for medical device post-market surveillance (materiovigilance). The concept of post market surveillance is linked to the concepts of vigilance and market surveillance. A manufacturer of medical devices is required to report incidents (serious adverse ...
IEC 62304 – medical device software – software life cycle processes [1] is an international standard published by the International Electrotechnical Commission (IEC). The standard specifies life cycle requirements for the development of medical software and software within medical devices.